SLOSED5
December 2024
TRF1213
PRODUCTION DATA
1
1
Features
2
Applications
3
Description
4
Pin Configuration and Functions
5
Specifications
5.1
Absolute Maximum Ratings
5.2
ESD Ratings
5.3
Recommended Operating Conditions
5.4
Thermal Information
5.5
Electrical Characteristics
5.6
Typical Characteristics
6
Detailed Description
6.1
Overview
6.2
Functional Block Diagram
6.3
Feature Description
6.3.1
Fully-Differential Amplifier
6.3.2
Single Supply Operation
6.4
Device Functional Modes
6.4.1
Power-Down Mode
7
Application and Implementation
7.1
Application Information
7.1.1
Driving a High-Speed ADC
7.1.2
Calculating Output Voltage Swing
7.1.3
Thermal Considerations
7.2
Typical Applications
7.2.1
TRF1213 in Receive Chain
7.2.1.1
Design Requirements
7.2.1.2
Detailed Design Procedure
7.2.1.3
Application Curve
7.3
Power Supply Recommendations
7.4
Layout
7.4.1
Layout Guidelines
7.4.2
Layout Example
8
Device and Documentation Support
8.1
Device Support
8.1.1
Third-Party Products Disclaimer
8.2
Documentation Support
8.2.1
Related Documentation
8.3
Receiving Notification of Documentation Updates
8.4
Support Resources
8.5
Trademarks
8.6
Electrostatic Discharge Caution
8.7
Glossary
9
Revision History
10
Mechanical, Packaging, and Orderable Information
5.2
ESD Ratings
VALUE
UNIT
V
(ESD)
Electrostatic discharge
Human body model (HBM), per ANSI/ESDA/JEDEC JS-001, all pins
(1)
±1000
V
Charged device model (CDM), per ANSI/ESDA/JEDEC JS-002, all pins
(2)
±250
(1)
JEDEC document JEP155 states that 500V HBM allows safe manufacturing with a standard ESD control process.
(2)
JEDEC document JEP157 states that 250V CDM allows safe manufacturing with a standard ESD control process.