SLVSG43B
December 2023 – July 2025
TPSI3100-Q1
PRODUCTION DATA
1
1
Features
2
Applications
3
Description
4
Device Comparison Table
5
Pin Configuration and Functions
6
Specifications
6.1
Absolute Maximum Ratings
6.2
ESD Ratings
6.3
Recommended Operating Conditions
6.4
Thermal Information
6.5
Power Ratings
6.6
Insulation Specifications
6.7
Safety-Related Certifications
6.8
Safety Limiting Values
6.9
Electrical Characteristics
6.10
Switching Characteristics
6.11
Insulation Characteristic Curves
6.12
Typical Characteristics
7
Parameter Measurement Information
8
Detailed Description
8.1
Overview
8.2
Functional Block Diagram
8.3
Feature Description
8.3.1
Transmission of the Enable State
8.3.2
Power Transmission
8.3.3
Gate Driver
8.3.4
Chip Enable (CE)
8.3.5
Comparators
8.3.5.1
Fault Comparator
8.3.5.2
Alarm Comparator
8.3.5.3
Comparator De-glitch
8.3.6
VDDP, VDDH, and VDDM Undervoltage Lockout (UVLO)
8.3.7
Keep-Off Circuitry
8.3.8
Thermal Shutdown
8.4
Device Operation
8.5
Device Functional Modes
9
Application and Implementation
9.1
Application Information
9.2
Typical Application
9.2.1
Design Requirements
9.2.2
Detailed Design Procedure
9.2.2.1
CDIV1, CDIV2 Capacitance
9.2.2.2
Start-up Time and Recovery Time
9.2.2.3
RSHUNT, R1, and R2 Selection
9.2.2.4
Overcurrent Fault Error
9.2.2.5
Overcurrent Alarm Error
9.2.2.6
VDDP Capacitance, CVDDP
9.2.3
Application Curves
9.3
Power Supply Recommendations
9.4
Layout
9.4.1
Layout Guidelines
9.4.2
Layout Example
10
Device and Documentation Support
10.1
Documentation Support
10.1.1
Related Documentation
10.2
Receiving Notification of Documentation Updates
10.3
Support Resources
10.4
Trademarks
10.5
Electrostatic Discharge Caution
10.6
Glossary
11
Revision History
12
Mechanical, Packaging, and Orderable Information
1
Features
Drives external power switches (MOSFETs, IGBTs, SiC FETs, SCRs)
Integrated bias supply, no isolated secondary supply required
17V
gate drive, 1.5A and 2.5A peak source and sink current
5kV
RMS
reinforced isolation
Up to 25mW, 5V supply for external auxiliary circuitry
Dual isolated high-speed comparators with integrated voltage reference ±1.5%
Open-drain outputs for fault and alarm indicators
AEC Q-100 qualified for automotive applications:
Temperature grade 1: –40°C to +125°C, T
A
Functional Safety-Capable
Documentation available to aid functional safety system design
Safety-related certifications
Planned: 7070V
PK
reinforced isolation per DIN EN IEC 60747-17 (VDE 0884-17)
Planned: 5kV
RMS
isolation for 1 minute per UL 1577