SLVSHK6A March 2025 – March 2026 TPS61381-Q1
PRODUCTION DATA
TPS61381-Q1 triggers maximum duty cycle limitation when the low-side MOS off time is about 100ns. When VBUB is too low and the max duty cycle is met, the device clamps its duty and output voltage cannot be regulated. So the available Vin range is limited by: