SNAS849A December 2024 – July 2026 LMX2624-SP
PRODUCTION DATA
The state machine clock (SM clock) is a divided down version of the OSCin signal that is used internally in the device. This divide value 1, 2, 4, 8, or 16 and is determined by CAL_CLK_DIV programming word (described in the programming section). The device support max. state machine clock frequency up to 50MHz. This state machine clock impacts VCO calibration. The state machine clock is calculated as fSM = fOSC / 2CAL_CLK_DIV.