SNAU287 November   2023

 

  1.   1
  2.   Description
  3.   Features
  4.   4
  5. 1Evaluation Module Overview
    1. 1.1 Introduction
    2. 1.2 Kit Contents
  6. 2Hardware
    1. 2.1 Evaluation Setup Requirement
    2. 2.2 Configuring the EVM
      1. 2.2.1 Configuring the Power Supply
      2. 2.2.2 Configuring the Control Pins
      3. 2.2.3 Configuring the Clock Outputs
      4. 2.2.4 Using the USB Interface Connection
      5. 2.2.5 EVM Quick Start Guide
    3. 2.3 Modes of Operation
  7. 3Software
    1. 3.1 Using TICS Pro with the LMK3H0102EVM
      1. 3.1.1 Using the LMK3H0102 Wizard
        1. 3.1.1.1 Frequency Plan
        2. 3.1.1.2 Output Formats
        3. 3.1.1.3 Output Enable Pin
        4. 3.1.1.4 OTP Options
        5. 3.1.1.5 Review
        6. 3.1.1.6 Design Report
      2. 3.1.2 Live Debugger
        1. 3.1.2.1 FODs
        2. 3.1.2.2 Outputs
        3. 3.1.2.3 Others
      3. 3.1.3 Programming
        1. 3.1.3.1 Registers
        2. 3.1.3.2 OTP Configuration
      4. 3.1.4 Help
        1. 3.1.4.1 Contact TI
    2. 3.2 Using TI’s USB2ANY Module for In-System Programming of the LMK3H0102
      1. 3.2.1 USB2ANY Board Connections
      2. 3.2.2 Ordering a USB2ANY Module
  8. 4Hardware Design Files
    1. 4.1 Schematics
    2. 4.2 PCB Layout
    3. 4.3 Bill of Materials
  9. 5Additional Information
    1.     Trademarks
  10. 6Related Documentation

EVM Quick Start Guide

The following guide allows the user to quickly configure the LMK3H0102EVM to evaluate the pre-programmed I2C or OTP configurations.

  1. If using software to program the device registers using I2C, install the TICS Pro software.

  2. Confirm the EVM default power configuration is set per Figure 3-2/Table 3-1 to power the LMK3H0102 using the on-board DC/DC converters with VDD = VDDO = 3.3 V.

  3. Set the control pin jumpers to select the desired start-up mode, as well as the other pin configuration settings, according to Table 3-2 for OTP Mode or Table 3-3 for I2C Mode. The default configuration is for I2C Mode.

    1. For OTP mode, Table 3-4 shows the default settings of the different OTP pages for the LMK3H0102V33 preprogrammed device configuration.

  4. Connect the micro-B USB cable to the micro-B USB port of the EVM, and connect the USB-A end to a PC.

  5. Observe any active clock on the OUT[1:0] SMA ports.

    1. OUT0 is AC-coupled, and OUT1 is DC-coupled.

    2. REF_CTRL is DC-coupled to the SMAs with a 33-Ω termination resistor in series.

    3. Use 50-Ω coax cables to connect the test equipment to the output SMA ports. If making a single-ended measurement on a differential output, terminate the unused SMA port with a 50-Ω load.

    4. To minimize output clock switching noise from affecting jitter-sensitive measurements, terminate any unused active output clock pair using 50-Ω SMA loads; otherwise, power-down unused output clocks via register programming.

Table 2-4 LMK3H0102 Start-up Settings
ParameterOTP Page 0OTP Page 1OTP Page 2OTP Page 3
OUT0 Frequency100 MHz100 MHz100 MHz100 MHz
OUT0 Output Format100-Ω LP-HCSL100-Ω LP-HCSL100-Ω LP-HCSL100-Ω LP-HCSL
OUT0 EnableEnableEnableEnableEnable
OUT0 Slew Rate2.3 to 3.4 V/ns2.3 to 3.4 V/ns2.3 to 3.4 V/ns2.3 to 3.4 V/ns
OUT0 Amplitude755 mV (typical)755 mV (typical)755 mV (typical)755 mV (typical)
OUT0 Disable BehaviorGNDGNDGNDGND
OUT1 Frequency100 MHz100 MHz100 MHz100 MHz
OUT1 Output Format100-Ω LP-HCSL100-Ω LP-HCSL100-Ω LP-HCSL100- LP-HCSL
OUT1 EnableEnableEnableEnableEnable
OUT1 Slew Rate2.3 to 3.4 V/ns2.3 to 3.4 V/ns2.3 to 3.4 V/ns2.3 to 3.4 V/ns
OUT1 Amplitude755 mV (typical)755 mV (typical)755 mV (typical)755 mV (typical)
OUT1 Disable BehaviorGNDGNDGNDGND
REF_CTRL BehaviorCLK_READYCLK_READYCLK_READYCLK_READY
FOD0 Frequency200 MHz200 MHz200 MHz200 MHz
FOD1 Frequency200 MHz200 MHz200 MHz200 MHz
SSC EnableDisableDisableDisableDisable
SSC Modulation TypeDown-spreadDown-spreadDown-spreadDown-spread
SSC Modulation Depth0%–0.1%–0.3%–0.5%