SNLA437A December   2023  – October 2025 DP83822H , DP83822HF , DP83822I , DP83822IF , DP83826I

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1DP83822 Application Overview
  5. 2Troubleshooting the PHY Application
    1. 2.1 Schematic and Layout Checklist
    2. 2.2 Device Health Checks
      1. 2.2.1 Power Supply Ramp Sequence Check
        1. 2.2.1.1 Power Supply Ramp with Unstable XI Clock
      2. 2.2.2 Voltage Checks
      3. 2.2.3 Probe the RESET_N Signal
      4. 2.2.4 Probe the RBIAS pin
      5. 2.2.5 Probe the XI Clock
      6. 2.2.6 Probe the Strap Pins During Initialization
      7. 2.2.7 Probe the Serial Management Interface (MDC, MDIO) Signals
        1. 2.2.7.1 Read and Check Register Values
          1. 2.2.7.1.1 Extended Register Access
    3. 2.3 MDI Health Checks
      1. 2.3.1 Magnetics
      2. 2.3.2 Probe the MDI Signals
      3. 2.3.3 Link Quality Check
      4. 2.3.4 Debug the Fiber Connection
      5. 2.3.5 Debug the Start of Frame Detect
      6. 2.3.6 Compliance
    4. 2.4 MII Health Checks
      1. 2.4.1 MII Check
      2. 2.4.2 RMII Check
      3. 2.4.3 RGMII Check
    5. 2.5 Loopback and PRBS
      1. 2.5.1 Loopback Modes
      2. 2.5.2 Transmitting and Receiving Packets With the MAC
      3. 2.5.3 Transmitting and Receiving Packets With BIST
  6. 3Tools and References
    1. 3.1 DP83822 Register Access
    2. 3.2 Software and Driver Debug on Linux
      1. 3.2.1 Common Terminal Outputs and Solutions
  7. 4Summary
  8. 5References
  9. 6Revision History
Extended Register Access

To read and write registers in extended register space, see the following procedures:

Write procedure for MMD "1F" registers:

write reg<000D> = 0x001F

write reg<000E> = <address>

write reg<000D> = 0x401F

write reg<000E> = <value>

Read procedure for MMD "1F" registers:

write reg<000D> = 0x001F

write reg<000E> = <address>

write reg<000D> = 0x401F

read reg<000E>

To write a register in the extended register set and automatically increment the address register to the next higher value following the write operation:

Write (Post Increment) procedure for MMD "1F" registers:

write reg<000D> = 0x001F

write reg<000E> = <address>

write reg<000D> = 0x401F

write reg<000E> = 0x0C50

write reg<000E> = <value>

To read a register in the extended register set and automatically increment the address register to the next higher value following the read operation:

Read (Post Increment) procedure for MMD "1F" registers:

write reg<000D> = 0x001F

write reg<000E> = <address>

write reg<000D> = 0x801F

read reg<000E>

read reg<000E>

Note: Above write and read procedure is normally used for registers with address greater than 0x001F, but the procedure can also be used for any address in general.