SNLA498 August   2026 DS90UB948-Q1 , DS90UB954-Q1 , DS90UB960-Q1 , DS90UB984-Q1 , DS90UB988-Q1

 

  1.   1
  2.   Abstract
  3. 1Fundamentals of S-Parameter Theory
    1. 1.1 Characteristic Impedance Explained
    2. 1.2 Reflection Coefficient Explained
    3. 1.3 Insertion Loss Explained
    4. 1.4 Return Loss Explained
    5. 1.5 Two-Port and Four-Port S-Parameters Explained
  4. 2S-Parameter Measurement Methods and Calibration Techniques
    1. 2.1 Introduction to Vector Network Analyzer Principles
    2. 2.2 TDR Measurement Explained
    3. 2.3 VNA Calibration Operating Procedure
    4. 2.4 Test Methods for S11 and S21
  5. 3FPD-Link Channel Specification Analysis
    1. 3.1 Overview of Total Link, PCB, and Cable Channel Specifications
    2. 3.2 Channel Specification Analysis
    3. 3.3 Key Design and Test Considerations for the FPD-Link Channel Specification
  6. 4Conclusion
  7. 5References

Characteristic Impedance Explained

Characteristic Impedance (Z0) is the "wave impedance" exhibited by the interaction between electric and magnetic fields as an electromagnetic wave propagates through a transmission line medium. At high frequencies, when the conductor length exceeds 1/10 of the signal wavelength, the conductor can no longer be treated as an ideal conductor and must be analyzed using a distributed parameter model (RLCG model).

Theoretical Basis: According to the Telegrapher's Equations, characteristic impedance is determined by the distributed inductance (L) and distributed capacitance (C) of the transmission line. For an ideal lossless line, it is calculated as:

Equation 1. Z 0 = L C

In PCB layout design, the following factors affect characteristic impedance:

  1. Trace Width (W): The conductor width directly affects the capacitance component. As trace width increases, the capacitance between the conductor and the reference plane increases, resulting in lower characteristic impedance. For example, when a microstrip line width increases from 5mil to 10mil, under the same dielectric conditions, characteristic impedance may decrease from 70Ω to 35Ω.
  2. Dielectric Thickness (H): The distance between the signal layer and the reference plane. Increasing dielectric thickness reduces the capacitance per unit length, thereby increasing characteristic impedance. For example, increasing dielectric thickness from 4 mil to 8mil may raise characteristic impedance from 50Ω to 70Ω.
  3. Copper Thickness (T): Conductor thickness affects the fringing field distribution. As copper thickness increases, the fringing capacitance effect intensifies, and characteristic impedance decreases slightly. Typically, 1oz copper (1.4mil) results in characteristic impedance approximately 2–3Ω lower than 0.5oz copper (0.7mil).
  4. Dielectric Constant (εr): An inherent property of the dielectric material. Higher εr values result in greater capacitance per unit length and lower characteristic impedance. For example, under the same geometric dimensions, FR4 material with εr = 4.5 yields characteristic impedance approximately 15% lower than high-frequency material with εr = 3.5.

There are two PCB trace models: microstrip line and stripline.

  1. Microstrip Line

    Structural Characteristics: The signal conductor is located on the PCB surface, with the dielectric substrate and reference plane beneath.

    Characteristics: Partially exposed to air, the effective dielectric constant lies between that of air and the substrate material.

    Typical Applications: High-speed signal routing on outer layers.

    Advantages: Easy routing and testing.

    Impedance Calculation Formula:

    Equation 2. Z 0 = 87 ε r + 1.41 l n 5.98 H 0.8 W + T
  2. Stripline

    Structural Characteristics: The signal conductor is completely embedded in the dielectric between two reference planes.

    Characteristics: Fully surrounded by dielectric, with a more uniform electric field distribution compared to microstrip.

    Typical Applications: High-speed signal routing on inner layers.

    Advantages: Better electromagnetic shielding performance.

    Impedance Calculation Formula:

    Equation 3. Z 0 = 60 ε r l n 1.9 2 H + T 0.8 W + T

In automotive applications, to achieve maximum power transfer and minimize reflections, impedance control standards are strictly defined: Coaxial Cable (Coax): Standard single-ended impedance is 50Ω. Shielded Twisted Pair (STP): Standard differential impedance is 100Ω. Any impedance discontinuities—such as connectors, vias, or trace width changes—cause signal reflections, thereby affecting signal integrity.