SNLS505H July 2016 – July 2026 DP83822H , DP83822HF , DP83822I , DP83822IF
PRODUCTION DATA
If an external clock source is used, XI must be tied to the clock source and XO must be left floating. The amplitude of the oscillator must be a nominal voltage of VDDIO.
The DP83822 requires Clock to be present at PoR. In case clock is delayed, pulldown on XI is recommended to avoid spurious signal latch-up.