SNLS676B May 2022 – July 2026 DP83TC813R-Q1 , DP83TC813S-Q1
PRODUCTION DATA
the DP83TC813-Q1 supports all four PMA compliance test modes required in IEEE 802.3bw, sub-clause 96.5.2. These compliance test modes include:
TX_TCLK can be routed to CLKOUT/LED_1 pin for 100BASE-T1 Follower Jitter measurement. This can be enabled via register 0x45F. The device must be configured in Follower mode.