SNOSDM7A August 2025 – April 2026 OPA4H838-SEP
PRODUCTION DATA
The OPA4H838-SEP family of operational amplifiers uses an auto-calibration technique with a time-continuous, 200kHz operational amplifier in the signal path. This amplifier is zero-corrected every 5µs using a proprietary technique. At power-up, the amplifier requires approximately 1ms to achieve the specified VOS accuracy. This design has no aliasing or flicker noise.