Figure 4-1 and
Figure 4-2 show the device naming nomenclature of the
TPS37100 and
TPS37102. For a detailed breakdown of device part number by features, thresholds,
and analog out scale see
Table 4-1 for more details. Contact TI sales representatives or on
TI's E2E™
forum for detail and availability of other options.
Table 4-1 Available Devices
| ORDERABLE PART NAME |
Feature |
OV / UV
SETTINGS (1)
(2) |
OUT A / OUT B SETTINGS |
TIME DELAY |
ANALOG
OUT SCALE |
| TPS37100W41DDYYR |
Analog
Out |
VITP: 832mV (ADJ)
VITN: 768mV (ADJ)
HYST: 1%
|
OUT A: VITN &
VITP
OUT B: VITN &
VITP
|
CTS: Enabled
CTR: Enabled
|
0.75 |
(1) For listed percentage denotes hysteresis
tolerance, see
Section 6.5 for
more information
(2) V
ITN or V
ITP
threshold with ADJ denotes an adjustable voltage threshold set by an external resistor
divider, see
Section 7.3.2.1 for
more information on how to set the threshold.
- Adjustable OV or UV only options
threshold is 800mV.
- Adjustable Window option thresholds only
available with 1% hysteresis.
- For OV only and UV only OUT A/B combined is default. Window can be
either OUT A/B combined or standard. Refer to Section 7.3.3.