SNVSD08 February 2026 LM34938-Q1
ADVANCE INFORMATION
For stable current loop operation and to avoid subharmonic oscillations, the slope resistor must be selected based on Equation 40.
For the calculation of the mSC value for the Slope Compensation, use the effective inductance at the maximum inductor current (set by the current limit). With a RCS of 2.5mΩ the current limit is set to 20A (typically). The inductance of the used inductor decreases to Leff =2.5μH at this peak current.