SWRZ166A November 2024 – June 2025 AWR2944P
Incorrect histogram output with 48pt Radix-3 FFT and histogram enabled in HWA
AWR2944P, AWR2E44P, AWR2944-ECO, AWR2E44-ECO, AWR2944LC, AWR2E44LC
If FFT core engine is enabled with Radix-3 48pt FFT and histogram block enabled, histograms 24 to 47 are stored at an offset in the Histogram RAM. Similarly, if CDF threshold mode is enabled, CDF thresholds for histograms 24 to 47 can be stored at an offset.
Read the first 24 histogram values from offset 0 to 12, and the remaining 24 histogram values from 16 to 32.