Table 2-4 lists out the duty cycle of the PWM signal for various output voltages. A limitation on the accuracy of this measurement, is the quality of the PWM signal emitted from the function generator. Therefore, these measurements can vary depending on the PWM applied.
| DPWM (%) | VOUT (V) |
|---|---|
|
0 |
35.108 |
|
0.05 |
33.649 |
|
0.1 |
32.189 |
|
0.15 |
30.730 |
|
0.2 |
29.270 |
|
0.25 |
27.811 |
|
0.3 |
26.351 |
|
0.35 |
24.892 |
|
0.4 |
23.432 |
|
0.45 |
21.973 |
|
0.5 |
20.513 |
|
0.55 |
19.054 |
|
0.6 |
17.594 |
|
0.65 |
16.135 |
|
0.7 |
14.675 |
|
0.75 |
13.216 |
|
0.8 |
11.756 |
|
0.85 |
10.297 |
|
0.9 |
8.837 |
|
0.95 |
7.378 |
|
1 |
5.918 |