TIDT423A December 2024 – January 2025
Short-circuit protection was performed at PCB board end. Auto recovery after short was removed.
CH1: Vds primary, CH2:VCC, CH3: Vout, CH4: Iout
Figure 3-48 Short Circuit at PCB End and Recovery When
Short Circuit Removed, 264VAC