TIDT443 July   2025

 

  1.   1
  2.   Description
  3.   Resources
  4.   Features
  5.   Applications
  6. 1Test Prerequisites
    1. 1.1 Voltage and Current Requirements
    2. 1.2 Required Equipment
    3. 1.3 Dimensions
    4. 1.4 Programming the TPS26744E-Q1
    5. 1.5 Test Setup
  7. 2Testing and Results
    1. 2.1 Efficiency and Loss Graphs
    2. 2.2 Efficiency and Loss Data
    3. 2.3 Thermal Images
  8. 3Waveforms
    1. 3.1 Output Transitions
    2. 3.2 Output Ripple

Output Ripple

All ripple scans done with 60Vin. Scope channel 2 blue is output AC ripple with 20MHz bandwidth, scope channel 3 purple is load current, scope channel 4 green is Vin.

PMP23501 Output Ripple
                            60Vin 20Vout No Load, Forced Continuous Conduction
                        Mode FCCM, 33mV Peak-To-Peak P-PFigure 3-9 Output Ripple 60Vin 20Vout No Load, Forced Continuous Conduction Mode FCCM, 33mV Peak-To-Peak P-P
PMP23501 Output Ripple
                            60Vin 5Vout No Load, FCCM, 14mV Peak-To-Peak
                        P-PFigure 3-11 Output Ripple 60Vin 5Vout No Load, FCCM, 14mV Peak-To-Peak P-P
PMP23501 Output Ripple
                            60Vin 20Vout 3A Load, FCCM, 38mV Peak-To-Peak
                        P-PFigure 3-10 Output Ripple 60Vin 20Vout 3A Load, FCCM, 38mV Peak-To-Peak P-P
PMP23501 Output Ripple
                            60Vin 5Vout 3A Load, FCCM, 16mV Peak-To-Peak
                        P-PFigure 3-12 Output Ripple 60Vin 5Vout 3A Load, FCCM, 16mV Peak-To-Peak P-P