TIDUF23A May 2023 – May 2025
The vertical offset of the power terminals of the module allows the bus-bar design to remain simple and cost-effective while maintaining a low power-loop inductance. A low-inductance bus bar is utilized to interconnect the DC-link capacitors (located under the bus bar) to the power modules. Again, the offset power module terminals enable the bus-bar assembly to have no bends or standoffs, which reduces cost and maximizes overlap. The capacitors are affixed as close as possible to minimize the total loop area. As Figure 3-10 shows, the bus bars consist of one flat plate connecting V+ terminals of the modules and capacitors followed by an insulator and then a second flat plate connecting to the raised V– terminals of the modules and the capacitors with coining or spacer for the capacitor terminal. The structure is simple enough that the product can be made with minimal fabrication which reduces the cost and lead-time.
Figure 3-10 Cross-Sectional View of Laminated Bus-Bar
Structure Showing Power LoopOptimized orientation for the capacitors is determined by measuring the inductance of three prototypes of the bussing geometry fabricated as two-layer PCBs. Between each prototype the capacitor terminals are rotated vertically, horizontally, and diagonally at 45 degrees. The horizontal orientation offered the lowest relative inductance with capacitors installed and is the orientation used for the laminated bussing.
The film capacitors serve two purposes: to close the high-frequency power loop and to provide local energy storage. To fulfill these roles the bus capacitors must be both low-inductance and have a high ripple current rating. The reference design features three Fischer & Tausche® CX100µ1100d51KF6 capacitors each rated to 100A ripple current and 100µF. A 1100V voltage rating is sufficient for operating on a 900V maximum DC bus with allowance for peak overshoots from aggressive switching rates. Each capacitor has an equivalent series inductance (ESL) of 10.5nH. Having three of these capacitors reduces the total ESL for the capacitor bank to 3.5nH which with a total measured inductance for the DC bussing and capacitors of 5.3nH means the bussing contributes 1.8nH. The 5.3nH inductance of the DC bus plus 6.7nH power loop inductance for the XM3 module results in a combined power loop inductance of 12nH which is lower than the stray inductance of many standard footprint modules alone.