PGA309

ACTIVO

Acondicionador de sensor programable PGA309 con salida de voltaje

Detalles del producto

PGA/VGA PGA Number of channels 2 Vs (max) (V) 5 Vs (min) (V) 2.7 Slew rate (typ) (V/µs) 0.5 Rating Catalog Operating temperature range (°C) -40 to 125
PGA/VGA PGA Number of channels 2 Vs (max) (V) 5 Vs (min) (V) 2.7 Slew rate (typ) (V/µs) 0.5 Rating Catalog Operating temperature range (°C) -40 to 125
TSSOP (PW) 16 32 mm² 5 x 6.4
  • Complete Bridge Sensor Conditioner
  • Voltage Output: Ratiometric or Absolute
  • Digital Cal: No Potentiometers/Sensor Trims
  • Sensor Error Compensation
    • Span, Offset, and Temperature Drifts
  • Low Error, Time-Stable
  • Sensor Linearization Circuitry
  • Temperature Sense: Internal or External
  • Calibration Lookup Table Logic
    • Uses External EEPROM (SOT23-5)
  • Over/Under-Scale Limiting
  • Sensor Fault Detection
  • +2.7V TO +5.5V Operation
  • –40°C to +125°C Operation
  • Small TSSOP-16 Package
  • APPLICATIONS
    • Bridge Sensors
    • Remote 4-20mA Transmitters
    • Strain, Load, and Weigh Scales
    • Automotive Sensors
  • APPLICATIONS
    • Hardware Designer’s Kit (PGA309EVM)
      • Temperature Eval of PGA309 + Sensor
      • Full Programming of PGA309
      • Sensor Compensation Analysis Tool
  • All other trademarks are the property of their respective owners.

    • Complete Bridge Sensor Conditioner
    • Voltage Output: Ratiometric or Absolute
    • Digital Cal: No Potentiometers/Sensor Trims
    • Sensor Error Compensation
      • Span, Offset, and Temperature Drifts
    • Low Error, Time-Stable
    • Sensor Linearization Circuitry
    • Temperature Sense: Internal or External
    • Calibration Lookup Table Logic
      • Uses External EEPROM (SOT23-5)
    • Over/Under-Scale Limiting
    • Sensor Fault Detection
    • +2.7V TO +5.5V Operation
    • –40°C to +125°C Operation
    • Small TSSOP-16 Package
    • APPLICATIONS
      • Bridge Sensors
      • Remote 4-20mA Transmitters
      • Strain, Load, and Weigh Scales
      • Automotive Sensors
  • APPLICATIONS
    • Hardware Designer’s Kit (PGA309EVM)
      • Temperature Eval of PGA309 + Sensor
      • Full Programming of PGA309
      • Sensor Compensation Analysis Tool
  • All other trademarks are the property of their respective owners.

    The PGA309 is a programmable analog signal conditioner designed for bridge sensors. The analog signal path amplifies the sensor signal and provides digital calibration for zero, span, zero drift, span drift, and sensor linearization errors with applied stress (pressure, strain, etc.). The calibration is done via a One-Wire digital serial interface or through a Two-Wire industry-standard connection. The calibration parameters are stored in external nonvolatile memory (typically SOT23-5) to eliminate manual trimming and achieve long-term stability.

    The all-analog signal path contains a 2x2 input multiplexer (mux), auto-zero programmable-gain instrumentation amplifier, linearization circuit, voltage reference, internal oscillator, control logic, and an output amplifier. Programmable level shifting compensates for sensor dc offsets.

    The core of the PGA309 is the precision, low-drift, no 1/f noise Front-End PGA (Programmable Gain Amplifier). The overall gain of the Front-End PGA + Output Amplifier can be adjusted from 2.7V/V to 1152V/V. The polarity of the inputs can be switched through the input mux to accommodate sensors with unknown polarity output. The Fault Monitor circuit detects and signals sensor burnout, overload, and system fault conditions.

    For detailed application information, see the PGA309 User's Guide (SBOU024) available for download at www.ti.com.

    The PGA309 is a programmable analog signal conditioner designed for bridge sensors. The analog signal path amplifies the sensor signal and provides digital calibration for zero, span, zero drift, span drift, and sensor linearization errors with applied stress (pressure, strain, etc.). The calibration is done via a One-Wire digital serial interface or through a Two-Wire industry-standard connection. The calibration parameters are stored in external nonvolatile memory (typically SOT23-5) to eliminate manual trimming and achieve long-term stability.

    The all-analog signal path contains a 2x2 input multiplexer (mux), auto-zero programmable-gain instrumentation amplifier, linearization circuit, voltage reference, internal oscillator, control logic, and an output amplifier. Programmable level shifting compensates for sensor dc offsets.

    The core of the PGA309 is the precision, low-drift, no 1/f noise Front-End PGA (Programmable Gain Amplifier). The overall gain of the Front-End PGA + Output Amplifier can be adjusted from 2.7V/V to 1152V/V. The polarity of the inputs can be switched through the input mux to accommodate sensors with unknown polarity output. The Fault Monitor circuit detects and signals sensor burnout, overload, and system fault conditions.

    For detailed application information, see the PGA309 User's Guide (SBOU024) available for download at www.ti.com.

    Descargar Ver vídeo con transcripción Video

    Productos similares que pueden interesarle

    open-in-new Comparar alternativas
    Misma funcionalidad con diferente configuración de pines que el dispositivo comparado
    PGA113 ACTIVO Desplazamiento a cero, desplazamiento de 100 µV, ruido de 12 nV/√Hz, amplificador de ganancia progra PGA113 is a similar device but not the same functionality, offering wider gain range, 4 calibration channels, 2 channel MUX, and SPI interface

    Documentación técnica

    star =Principal documentación para este producto seleccionada por TI
    No se encontraron resultados. Borre su búsqueda y vuelva a intentarlo.
    Ver todo 18
    Tipo Título Fecha
    * Data sheet Voltage Output Programmable Sensor Conditioner datasheet (Rev. C) 14 ene 2011
    User guide PGA309 User's Guide (Rev. C) PDF | HTML 28 jul 2023
    Application brief How to Select Amplifiers for Pressure Transmitter Applications (Rev. B) PDF | HTML 14 feb 2023
    Application brief Multichannel Analog Input Modules for PLC Equipment 04 ene 2019
    EVM User's guide Multi-Cal-System Evaluation Module User's Guide (Rev. B) 15 sep 2016
    EVM User's guide PGA309EVM-USB User Guide (Rev. B) 31 ago 2016
    Analog Design Journal Ratiometric measurement in the context of LVDT-sensor signal conditioning 21 jul 2016
    Analog Design Journal 4Q 2011 Issue Analog Applications Journal 09 nov 2011
    Analog Design Journal Analog linearization of resistance temperature detectors 09 nov 2011
    EVM User's guide Multi-Cal-PGA309 System User Guide 27 abr 2011
    User guide Multi-Cal-Master User's Guide 22 ago 2010
    User guide Multi-Cal-Test Users Guide 22 ago 2010
    Application note Using the XTR115 with the PGA309 to Generate 4mA to 20mA Output (Rev. B) 20 abr 2006
    Application note PGA309 Quick Start System Reference Guide (Rev. C) 13 ene 2006
    Application note PGA309 Noise Filtering (Rev. A) 28 nov 2005
    Application note Practical Technique for Minimizing the Number of Measurements in Sensor Signal 28 jun 2005
    Application note PGA309 Microcontroller Application 07 jun 2005
    User guide Using PGA309 for Sensor Compensation 11 mar 2004

    Diseño y desarrollo

    Para conocer los términos adicionales o los recursos necesarios, haga clic en cualquier título de abajo para ver la página de detalles cuando esté disponible.

    Placa de evaluación

    MULTI-CAL-SYSTEM — Kit de inicio básico de Multi-Cal-Sistema

    The Multi-Cal-System is a system of evaluation modules and accessories that can be used to calibrate multiple PGA308 sensor modules. The Multi-Cal-System can be configured to calibrate from 8 to 64 PGA308s simultaneously. The key component of the Multi-Cal-System is the Multi-Cal-System Starter (...)

    Guía del usuario: PDF
    Placa de evaluación

    PGA309EVM-USB — Módulo de evaluación PGA309

    The PGA309EVM-USB key hardware consists of two boards, PGA309 Test Board and USB DAQ Platform. The PGA309 Test Board contains the PGA309, terminal strips for external connections, several jumpers for device configuration, and support circuitry. The PGA309 Test Board can be used to fully test your (...)

    Guía del usuario: PDF
    Placa de evaluación

    SENSOREMULATOREVM — Módulo de evaluación EVM de emulador de sensor

    The SensorEmulatorEVM provides a complete system for strain and temperature emulation of voltage-excited bridge sensors. The SensorEmulatorEVM uses rotary selector switches and potentiometers to emulate the operation of a voltage-excited Wheatstone resistive bridge sensor at discrete operating (...)

    Soporte de software

    SBOC320 PGA309EVM-USB Software

    Productos y hardware compatibles

    Productos y hardware compatibles

    Productos
    Amplificadores de ganancia programable y variable (PGA y VGA)
    PGA309 Acondicionador de sensor programable PGA309 con salida de voltaje
    Desarrollo de hardware
    Placa de evaluación
    PGA309EVM-USB Módulo de evaluación PGA309
    Soporte de software

    SBOC394 PGA309EVM-USB Source Code

    Productos y hardware compatibles

    Productos y hardware compatibles

    Productos
    Amplificadores de ganancia programable y variable (PGA y VGA)
    PGA309 Acondicionador de sensor programable PGA309 con salida de voltaje
    Desarrollo de hardware
    Placa de evaluación
    PGA309EVM-USB Módulo de evaluación PGA309
    Soporte de software

    SBOC401 Multi-Cal-PGA309 System Software

    Productos y hardware compatibles

    Productos y hardware compatibles

    Productos
    Amplificadores de ganancia programable y variable (PGA y VGA)
    PGA309 Acondicionador de sensor programable PGA309 con salida de voltaje
    Desarrollo de hardware
    Placa de evaluación
    MULTI-CAL-SYSTEM Kit de inicio básico de Multi-Cal-Sistema
    Herramienta de cálculo

    SBOC065 Generate Simulated Values

    Productos y hardware compatibles

    Productos y hardware compatibles

    Productos
    Amplificadores de ganancia programable y variable (PGA y VGA)
    PGA309 Acondicionador de sensor programable PGA309 con salida de voltaje
    Desarrollo de hardware
    Placa de evaluación
    SENSOREMULATOREVM Módulo de evaluación EVM de emulador de sensor
    Herramienta de cálculo

    SBOC132 PGA309 Calculator Source Code

    Productos y hardware compatibles

    Productos y hardware compatibles

    Productos
    Amplificadores de ganancia programable y variable (PGA y VGA)
    PGA309 Acondicionador de sensor programable PGA309 con salida de voltaje
    Herramienta de cálculo

    SLOR088 PGA309EVM Software (Rev 1.5.17) – Includes PGA309 Calculator Software

    Productos y hardware compatibles

    Productos y hardware compatibles

    Productos
    Amplificadores de ganancia programable y variable (PGA y VGA)
    PGA309 Acondicionador de sensor programable PGA309 con salida de voltaje
    Herramienta de cálculo

    SLVC073 PGA309 Gain Calculator

    Productos y hardware compatibles

    Productos y hardware compatibles

    Productos
    Amplificadores de ganancia programable y variable (PGA y VGA)
    PGA309 Acondicionador de sensor programable PGA309 con salida de voltaje
    Esquema

    PGA309EVM-USB Schematic

    SBOR010.PDF (44 KB)
    Esquema

    Multi-Cal-Master Schematics

    SBOR011.ZIP (585 KB)
    Esquema

    Multi-Cal-Slave Schematic

    SBOR015.PDF (535 KB)
    Herramienta de simulación

    PSPICE-FOR-TI — PSpice® para herramienta de diseño y simulación de TI

    PSpice® for TI is a design and simulation environment that helps evaluate functionality of analog circuits. This full-featured, design and simulation suite uses an analog analysis engine from Cadence®. Available at no cost, PSpice for TI includes one of the largest model libraries in the (...)
    Herramienta de simulación

    TINA-TI — Programa de simulación analógica basado en SPICE

    TINA-TI provides all the conventional DC, transient and frequency domain analysis of SPICE and much more. TINA has extensive post-processing capability that allows you to format results the way you want them. Virtual instruments allow you to select input waveforms and probe circuit nodes voltages (...)
    Guía del usuario: PDF
    Diseños de referencia

    TIPD126 — Bridge sensor signal conditioner with current loop output and EMC protection reference design

    This bridge sensor conditioner module delivers a well-regulated current output to a ground-referenced load. The first stage uses a mixed-signal programmable gain amplifier (PGA) to provide linearization and temperature compensation to a differential bridge sensor voltage. The second stage converts (...)
    Guía del usuario: PDF
    Esquema: PDF
    Paquete Pasadores Descargar
    TSSOP (PW) 16 Ver opciones

    Pedidos y calidad

    Información incluida:
    • RoHS
    • REACH
    • Marcado del dispositivo
    • Acabado de plomo/material de la bola
    • Clasificación de nivel de sensibilidad a la humedad (MSL) / reflujo máximo
    • Estimaciones de tiempo medio entre fallas (MTBF)/fallas en el tiempo (FIT)
    • Contenido del material
    • Resumen de calificaciones
    • Monitoreo continuo de confiabilidad
    Información incluida:
    • Lugar de fabricación
    • Lugar de ensamblaje

    Soporte y capacitación

    Foros de TI E2E™ con asistencia técnica de los ingenieros de TI

    El contenido lo proporcionan “tal como está” TI y los colaboradores de la comunidad y no constituye especificaciones de TI. Consulte los términos de uso.

    Si tiene preguntas sobre la calidad, el paquete o el pedido de productos de TI, consulte el soporte de TI. ​​​​​​​​​​​​​​

    Videos