產品詳細資料

PGA/VGA PGA Number of channels 2 Vs (min) (V) 2.7 Vs (max) (V) 5.5 Input type Differential Output type Single-ended Input offset drift (±) (typ) (µV/°C) 0.2 Interface type 1-wire, UART Noise at 1 kHz (typ) (V√Hz) 0.00000005 BW at Acl (MHz) 2 Acl, min spec gain (V/V) 4 Voltage gain (max) (V/V) 80 Gain (max) (dB) 64 Architecture CMOS Features Fault Detection Vos (offset voltage at 25°C) (typ) (mV) 0.005 Input voltage noise (typ) (µV√Hz) 0.05 Slew rate (typ) (V/µs) 0.6 Iq per channel (typ) (mA) 1.3 Gain error (typ) (%) 0.3 Gain drift (max) (ppm/°C) 6 Rating Catalog Operating temperature range (°C) -40 to 125
PGA/VGA PGA Number of channels 2 Vs (min) (V) 2.7 Vs (max) (V) 5.5 Input type Differential Output type Single-ended Input offset drift (±) (typ) (µV/°C) 0.2 Interface type 1-wire, UART Noise at 1 kHz (typ) (V√Hz) 0.00000005 BW at Acl (MHz) 2 Acl, min spec gain (V/V) 4 Voltage gain (max) (V/V) 80 Gain (max) (dB) 64 Architecture CMOS Features Fault Detection Vos (offset voltage at 25°C) (typ) (mV) 0.005 Input voltage noise (typ) (µV√Hz) 0.05 Slew rate (typ) (V/µs) 0.6 Iq per channel (typ) (mA) 1.3 Gain error (typ) (%) 0.3 Gain drift (max) (ppm/°C) 6 Rating Catalog Operating temperature range (°C) -40 to 125
VSON (DRK) 10 12 mm² (4 mm × 3 mm) VSSOP (DGS) 10 14.7 mm² (3 mm × 4.9 mm)
  • Digital Calibration for Bridge Sensors
  • Offset Select: Coarse and Fine
  • Gain Select: Coarse and Fine
  • Bridge Fault Monitor
  • Input Mux for Lead Swap
  • Over/Under Scale Limits
  • DOUT/VOUT Clamp Function
  • Seven Banks OTP Memory
  • One-Wire Digital UART Interface
  • Operating Voltage: +2.7V to +5.5V
  • Temperature Range: –40°C to +125°C
  • MSOP-10 and 3mm × 4mm DFN-10 Packages
  • Digital Calibration for Bridge Sensors
  • Offset Select: Coarse and Fine
  • Gain Select: Coarse and Fine
  • Bridge Fault Monitor
  • Input Mux for Lead Swap
  • Over/Under Scale Limits
  • DOUT/VOUT Clamp Function
  • Seven Banks OTP Memory
  • One-Wire Digital UART Interface
  • Operating Voltage: +2.7V to +5.5V
  • Temperature Range: –40°C to +125°C
  • MSOP-10 and 3mm × 4mm DFN-10 Packages

The PGA308 is a programmable analog sensor signal conditioner. The analog signal path amplifies the sensor signal and provides digital calibration for offset and gain. Calibration is done via the 1W pin, a digital One-Wire, UART-compatible interface. For three-terminal sensor modules, 1W may be connected to VOUT and the assembly programmed through the VOUT pin. Gain and offset calibration parameters are stored onboard in seven banks of one-time programmable (OTP) memory. The power-on reset (POR) OTP bank may be programmed a total of four times.

The all-analog signal path contains a 2×2 input multiplexer (mux) to allow electronic sensor lead swapping, a coarse offset adjust, an auto-zero programmable gain instrumentation amplifier (PGA), a fine gain adjust, a fine offset adjust, and a programmable gain output amplifier. Fault monitor circuitry detects and signals sensor burnout, overload, and system fault conditions. Over/under-scale limits provide additional means for system level diagnostics. The dual-use DOUT/VCLAMP pin can be used as a programmable digital output or as a VOUT over-voltage clamp.

For detailed application information, see the PGA308 User's Guide (SBOU069) available for download at www.ti.com.

The PGA308 is a programmable analog sensor signal conditioner. The analog signal path amplifies the sensor signal and provides digital calibration for offset and gain. Calibration is done via the 1W pin, a digital One-Wire, UART-compatible interface. For three-terminal sensor modules, 1W may be connected to VOUT and the assembly programmed through the VOUT pin. Gain and offset calibration parameters are stored onboard in seven banks of one-time programmable (OTP) memory. The power-on reset (POR) OTP bank may be programmed a total of four times.

The all-analog signal path contains a 2×2 input multiplexer (mux) to allow electronic sensor lead swapping, a coarse offset adjust, an auto-zero programmable gain instrumentation amplifier (PGA), a fine gain adjust, a fine offset adjust, and a programmable gain output amplifier. Fault monitor circuitry detects and signals sensor burnout, overload, and system fault conditions. Over/under-scale limits provide additional means for system level diagnostics. The dual-use DOUT/VCLAMP pin can be used as a programmable digital output or as a VOUT over-voltage clamp.

For detailed application information, see the PGA308 User's Guide (SBOU069) available for download at www.ti.com.

下載 觀看有字幕稿的影片 影片

您可能會感興趣的類似產品

open-in-new 比較替代產品
功能相同,但針腳輸出與所比較的裝置不同。
PGA113 現行 具 2 通道多工器的零漂移、100-µV 偏移、12-nV/√Hz 雜訊、RRO (範圍增益) 可編程增益放大器 PGA113 is a similar device but not the same functionality, offering wider gain range, 4 calibration channels, 2 channel MUX, and SPI interface

技術文件

找不到結果。請清除您的搜尋條件,然後再試一次。
檢視所有 12
重要文件 類型 標題 格式選項 下載最新的英文版本 日期
* 資料表 Single-Supply, Auto-Zero Sensor Amplifier with Programmable Gain and Offset datasheet (Rev. B) 2010/12/22
功能安全資訊 PGA308 Functional Safety, FIT Rate, Failure Mode Distribution and Pin FMA PDF | HTML 2024/6/20
Application brief Multichannel Analog Input Modules for PLC Equipment 2019/1/4
使用指南 PGA308 User's Guide (Rev. B) 2012/1/27
使用指南 Multi-Cal-PGA308 System User Guide 2011/4/29
使用指南 Multi-Cal-Interface User's Guide 2010/9/9
使用指南 Multi-Cal-Slave User's Guide 2010/9/9
使用指南 Multi-Cal-Cable User's Guide 2010/9/8
使用指南 Multi-Cal-Master User's Guide 2010/8/22
使用指南 Multi-Cal-Test Users Guide 2010/8/22
使用指南 tioScript Editor Users Guide 2008/8/26
使用指南 USB DAQ Platform User's Guide 2008/3/20

設計與開發

如需其他條款或必要資源,請按一下下方的任何標題以檢視詳細頁面 (如有)。

開發板

MULTI-CAL-SYSTEM — Multi-Cal-System 基礎入門套件

The Multi-Cal-System is a system of evaluation modules and accessories that can be used to calibrate multiple PGA308 sensor modules. The Multi-Cal-System can be configured to calibrate from 8 to 64 PGA308s simultaneously. The key component of the Multi-Cal-System is the Multi-Cal-System Starter (...)

使用指南: PDF
支援產品和硬體
有庫存
限制:
??asset.out-of-stock-ti_zh_TW??
無法提供
開發板

PGA308EVM — PGA308 評估模組

The PGA308EVM key hardware consists of two boards, PGA308 Test Board and USB DAQ Platform. The PGA308 Test Board contains the PGA308, terminal strips for external connections, several jumpers for device configuration, and support circuitry. The PGA308 Test Board can be used to fully test your (...)

使用指南: PDF
支援產品和硬體
有庫存
限制:
??asset.out-of-stock-ti_zh_TW??
無法提供
支援軟體

SBOC256 — PGA308EVM Source Code

支援產品和硬體
支援軟體

SBOC257 — PGA308EVM Software

支援產品和硬體
支援軟體

SBOC390 — Multi-Cal-PGA308 System Software

支援產品和硬體
支援軟體

SBOC391 — Multi-Cal-PGA308 System Source Code

支援產品和硬體
封裝 針腳 CAD 符號、佔位空間與 3D 模型
VSON (DRK) 10 Ultra Librarian
VSSOP (DGS) 10 Ultra Librarian

訂購與品質

支援與培訓

內含 TI 工程師技術支援的 TI E2E™ 論壇

內容係由 TI 和社群貢獻者依「現狀」提供,且不構成 TI 規範。檢視使用條款

若有關於品質、封裝或訂購 TI 產品的問題,請參閱 TI 支援。​​​​​​​​​​​​​​

影片