產品詳細資料

PGA/VGA VGA Number of channels 8 Vs (min) (V) 3.15 Vs (max) (V) 5.5 Input type Single-ended Output type Differential BW at Acl (MHz) 200 Acl, min spec gain (V/V) 1 Gain (max) (dB) 54 Features Analog Gain Set, Digital Gain Set, Shutdown Rating Catalog Operating temperature range (°C) -40 to 85
PGA/VGA VGA Number of channels 8 Vs (min) (V) 3.15 Vs (max) (V) 5.5 Input type Single-ended Output type Differential BW at Acl (MHz) 200 Acl, min spec gain (V/V) 1 Gain (max) (dB) 54 Features Analog Gain Set, Digital Gain Set, Shutdown Rating Catalog Operating temperature range (°C) -40 to 85
HTQFP (PZP) 100 256 mm² (16 mm × 16 mm)
  • 8-Channel Voltage Controlled Amplifier
    • LNA, VCAT, PGA, LPF, and CW Mixer
  • Programmable Low-Noise Amplifier (LNA)
    • 24/18/12 dB Gain
    • 0.25/0.5/1 VPP Linear Input Range
    • 0.63/0.7/0.9 nV/rtHz Input Referred Noise
    • Programmable Active Termination
  • 40 dB Low Noise Voltage Controlled Attenuator (VCAT)
  • 24/30 dB Programmable Gain Amplifier (PGA)
  • 3rd Order Linear Phase Low-Pass Filter (LPF)
    • 10, 15, 20, 30 MHz
    • Butterworth Characteristics
  • Noise/Power Optimizations (Full Chain)
    • 99 mW/CH at 0.75 nV/rtHz
    • 56 mW/CH at 1.1 nV/rtHz
    • 80 mW/CH at CW Mode
  • Excellent Device-to-Device Gain Matching
    • ±0.5 dB (typical) and ±1.05 dB (max)
  • Low Harmonic Distortion
  • Fast and Consistent Overload Recovery
  • Low Frequency Sonar Signal Processing
  • Passive Mixer for Continuous Wave Doppler (CWD)
    • Low Close-in Phase Noise –156 dBc/Hz at 1 KHz off 2.5 MHz Carrier
    • Phase Resolution of 1/16λ
    • Support 32X,16X, 8X, 4X and 1X CW Clocks
    • 12dB Suppression on 3rd and 5th Harmonics
    • Flexible Input Clocks
  • 14mm x 14mm, 100-pin TQFP
  • 8-Channel Voltage Controlled Amplifier
    • LNA, VCAT, PGA, LPF, and CW Mixer
  • Programmable Low-Noise Amplifier (LNA)
    • 24/18/12 dB Gain
    • 0.25/0.5/1 VPP Linear Input Range
    • 0.63/0.7/0.9 nV/rtHz Input Referred Noise
    • Programmable Active Termination
  • 40 dB Low Noise Voltage Controlled Attenuator (VCAT)
  • 24/30 dB Programmable Gain Amplifier (PGA)
  • 3rd Order Linear Phase Low-Pass Filter (LPF)
    • 10, 15, 20, 30 MHz
    • Butterworth Characteristics
  • Noise/Power Optimizations (Full Chain)
    • 99 mW/CH at 0.75 nV/rtHz
    • 56 mW/CH at 1.1 nV/rtHz
    • 80 mW/CH at CW Mode
  • Excellent Device-to-Device Gain Matching
    • ±0.5 dB (typical) and ±1.05 dB (max)
  • Low Harmonic Distortion
  • Fast and Consistent Overload Recovery
  • Low Frequency Sonar Signal Processing
  • Passive Mixer for Continuous Wave Doppler (CWD)
    • Low Close-in Phase Noise –156 dBc/Hz at 1 KHz off 2.5 MHz Carrier
    • Phase Resolution of 1/16λ
    • Support 32X,16X, 8X, 4X and 1X CW Clocks
    • 12dB Suppression on 3rd and 5th Harmonics
    • Flexible Input Clocks
  • 14mm x 14mm, 100-pin TQFP

The VCA5807 is an integrated Voltage Controlled Amplifier (VCA) specifically designed for ultrasound systems in which high performance and small size are required. The VCA5807 integrates a complete time-gain-control (TGC) imaging path and a continuous wave Doppler (CWD) path. It also enables users to select one of various power/noise combinations to optimize system performance. Therefore, the VCA5807 is a suitable ultrasound analog front end solution not only for high-end systems, but also for portable systems.

The VCA5807 contains eight channels of voltage controlled amplifier (VCA), and CW mixer. The VCA includes Low noise Amplifier(LNA), Voltage controlled Attenuator (VCAT), Programmable Gain Amplifier (PGA), and Low-Pass Filter (LPF). The LNA gain is programmable to support 250 mVPP to 1 VPP input signals. Programmable active termination is also supported by the LNA. The ultra-low noise VCAT provides an attenuation control range of 40dB and improves overall low gain SNR which benefits harmonic imaging and near field imaging. The PGA provides gain options of 24 dB and 30 dB. Before the ADC, a LPF can be configured as 10 MHz, 15 MHz, 20 MHz, or 30 MHz to support ultrasound applications with different frequencies. In addition, the signal chain of the VCA5807 can handle signal frequency lower than 100 KHz, which enables it to be used not only in ultrasound applications but also in sonar applications.

The VCA5807 integrates a low power passive mixer and a low noise summing amplifier to accomplish on-chip CWD beamformer. 16 selectable phase-delays can be applied to each analog input signal. Meanwhile a unique 3rd and 5th order harmonic suppression filter is implemented to enhance CW sensitivity.

The VCA5807 is available in a 14mm x 14mm, 100-pin TQFP package and it is specified for operation from -40°C to 85°C.

The VCA5807 is an integrated Voltage Controlled Amplifier (VCA) specifically designed for ultrasound systems in which high performance and small size are required. The VCA5807 integrates a complete time-gain-control (TGC) imaging path and a continuous wave Doppler (CWD) path. It also enables users to select one of various power/noise combinations to optimize system performance. Therefore, the VCA5807 is a suitable ultrasound analog front end solution not only for high-end systems, but also for portable systems.

The VCA5807 contains eight channels of voltage controlled amplifier (VCA), and CW mixer. The VCA includes Low noise Amplifier(LNA), Voltage controlled Attenuator (VCAT), Programmable Gain Amplifier (PGA), and Low-Pass Filter (LPF). The LNA gain is programmable to support 250 mVPP to 1 VPP input signals. Programmable active termination is also supported by the LNA. The ultra-low noise VCAT provides an attenuation control range of 40dB and improves overall low gain SNR which benefits harmonic imaging and near field imaging. The PGA provides gain options of 24 dB and 30 dB. Before the ADC, a LPF can be configured as 10 MHz, 15 MHz, 20 MHz, or 30 MHz to support ultrasound applications with different frequencies. In addition, the signal chain of the VCA5807 can handle signal frequency lower than 100 KHz, which enables it to be used not only in ultrasound applications but also in sonar applications.

The VCA5807 integrates a low power passive mixer and a low noise summing amplifier to accomplish on-chip CWD beamformer. 16 selectable phase-delays can be applied to each analog input signal. Meanwhile a unique 3rd and 5th order harmonic suppression filter is implemented to enhance CW sensitivity.

The VCA5807 is available in a 14mm x 14mm, 100-pin TQFP package and it is specified for operation from -40°C to 85°C.

下載 觀看有字幕稿的影片 影片

技術文件

找不到結果。請清除您的搜尋條件,然後再試一次。
檢視所有 1
重要文件 類型 標題 格式選項 下載最新的英文版本 日期
* 資料表 Fully Integrated, 8-Channel Voltage Controlled Amplifier for Ultrasound datasheet 2012/12/4

設計與開發

如需其他條款或必要資源,請按一下下方的任何標題以檢視詳細頁面 (如有)。

開發板

VCA5807EVM — VCA5807 評估模組

The VCA5807 is an integrated Voltage Controlled Amplifier(VCA) solution specifically designed for ultrasound systems in which high performance and small size are required. The VCA5807 integrates a complete time-gain-control(TGC) imaging path and a continuous wave Doppler(CWD) path. It also enables (...)

使用指南: PDF
支援產品和硬體
有庫存
限制:
??asset.out-of-stock-ti_zh_TW??
無法提供
開發模組 (EVM) 的 GUI

SLOC282 — VCA5807EVM GUI

支援產品和硬體
模擬型號

VCA5807 PSpice Model

SLOM347.ZIP (69 KB) - PSpice 模型
支援產品和硬體
模擬型號

VCA5807 PSpice Transient Model

SLOM346.ZIP (39 KB) - PSpice 模型
支援產品和硬體
模擬型號

VCA5807 TINA-TI Reference Design

SLOM340.TSC (106 KB) - TINA-TI 參考設計
支援產品和硬體
模擬型號

VCA5807 TINA-TI Spice Model

SLOM339.ZIP (63 KB) - TINA-TI Spice 模型
支援產品和硬體
模擬型號

VCA5807 TINA-TI Transient Reference Design

SLOM344.TSC (63 KB) - TINA-TI 參考設計
支援產品和硬體
模擬型號

VCA5807 TINA-TI Transient Spice Model

SLOM345.ZIP (35 KB) - TINA-TI Spice 模型
支援產品和硬體
封裝 針腳 CAD 符號、佔位空間與 3D 模型
HTQFP (PZP) 100 Ultra Librarian

訂購與品質

支援與培訓

內含 TI 工程師技術支援的 TI E2E™ 論壇

內容係由 TI 和社群貢獻者依「現狀」提供,且不構成 TI 規範。檢視使用條款

若有關於品質、封裝或訂購 TI 產品的問題,請參閱 TI 支援。​​​​​​​​​​​​​​

影片