SLUSCK1C July 2016 – June 2018 TPS546C20A
PRODUCTION DATA.
Refer to the PDF data sheet for device specific package drawings
The cmd bit controls how the device responds to the OPERATION command. This bit is used in conjunction with the cpr, pu, and on bits to determine start up.
BIT VALUE | ACTION |
---|---|
0 | Device ignores the “on” bit in the OPERATION command. |
1 | Device responds to the “on” bit in the OPERATION command. |