JAJSAR0B March   2007  – October 2017 LM95214

PRODUCTION DATA.  

  1. 特長
  2. アプリケーション
  3. 概要
    1.     リモート1温度エラー、TA=TD
  4. 改訂履歴
  5. 概要(続き)
  6. Pin Configuration and Functions
    1.     Pin Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics: Temperature-to-Digital Converter
    6. 7.6 Logic Electrical Characteristics: Digital DC Characteristics
    7. 7.7 Switching Characteristics: SMBus Digital
    8. 7.8 Typical Characteristics
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Conversion Sequence
      2. 8.3.2 Power-On-Default States
      3. 8.3.3 SMBus Interface
      4. 8.3.4 Temperature Conversion Sequence
        1. 8.3.4.1 Digital Filter
      5. 8.3.5 Fault Queue
      6. 8.3.6 Temperature Data Format
      7. 8.3.7 SMBDAT Open-Drain Output
      8. 8.3.8 TCRIT1, TCRIT2, and TCRIT3 Outputs
      9. 8.3.9 TCRIT Limits and TCRIT Outputs
    4. 8.4 Device Functional Modes
      1. 8.4.1 Diode Fault Detection
      2. 8.4.2 Communicating With the LM95214
      3. 8.4.3 Serial Interface Reset
      4. 8.4.4 One-Shot Conversion
    5. 8.5 Register Maps
      1. 8.5.1 LM95214 Registers
        1. 8.5.1.1 Value Registers
          1. 8.5.1.1.1 Local Value Registers
          2. 8.5.1.1.2 Remote Temperature Value Registers With Signed Format
          3. 8.5.1.1.3 Remote Temperature Value Registers With Unsigned Format
        2. 8.5.1.2 Diode Configuration Register
          1. 8.5.1.2.1 Remote 1-4 Offset
        3. 8.5.1.3 Configuration Registers
          1. 8.5.1.3.1 Main Configuration Register
          2. 8.5.1.3.2 Conversion Rate Register
          3. 8.5.1.3.3 Channel Conversion Enable
          4. 8.5.1.3.4 Filter Setting
          5. 8.5.1.3.5 1-Shot
        4. 8.5.1.4 Status Registers
          1. 8.5.1.4.1 Common Status Register
          2. 8.5.1.4.2 Status 1 Register (Diode Fault)
          3. 8.5.1.4.3 Status 2 (TCRIT1)
          4. 8.5.1.4.4 Status 3 (TCRIT2)
          5. 8.5.1.4.5 Status 4 (TCRIT3)
        5. 8.5.1.5 Mask Registers
          1. 8.5.1.5.1 TCRIT1 Mask Register
          2. 8.5.1.5.2 TCRIT2 Mask Registers
          3. 8.5.1.5.3 TCRIT3 Mask Register
        6. 8.5.1.6 Limit Registers
          1. 8.5.1.6.1 Local Limit Register
          2. 8.5.1.6.2 Remote Limit Registers
          3. 8.5.1.6.3 Common Tcrit Hysteresis Register
        7. 8.5.1.7 Identification Registers
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
    3. 9.3 Diode Non-Ideality
      1. 9.3.1 Diode Non-Ideality Factor Effect on Accuracy
      2. 9.3.2 Calculating Total System Accuracy
      3. 9.3.3 Compensating for Different Non-Ideality
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12デバイスおよびドキュメントのサポート
    1. 12.1 ドキュメントの更新通知を受け取る方法
    2. 12.2 コミュニティ・リソース
    3. 12.3 商標
    4. 12.4 静電気放電に関する注意事項
    5. 12.5 Glossary
  13. 13メカニカル、パッケージ、および注文情報

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Channel Conversion Enable

When a conversion is disabled for a particular channel it is skipped. The continuous conversion rate is effected all other conversion rates are not effected as extra standby time is inserted to compensate. See Conversion Rate Register description.

Register Name Command Byte
(Hex)
Read/
Write
D7 D6 D5 D4 D3 D2 D1 D0 POR Default (Hex)
Channel Conversion Enable 0×05 R/W R4CE R3CE R2CE R1CE LCE 0×1F
Bit(s) Bit Name Read/Write Description
7–5 RO Reserved – will report 0 when read.
4 R4CE R/W Remote 4 Temperature Conversion Enable
1– Remote 4 temp conversion enabled
0– Remote 4 temp conversion disabled
3 R3CE R/W Remote 3 Temperature Conversion Enable
1– Remote 3 temp conversion enabled
0– Remote 3 temp conversion disabled
2 R2CE R/W Remote 2 Temperature Conversion Enable
1– Remote 2 temp conversion enabled
0– Remote 2 temp conversion disabled
1 R1CE R/W Remote 1 Temperature Conversion Enable
1– Remote 1 temp conversion enabled
0– Remote 1 temp conversion disabled
0 LCE R/W Local Temperature Conversion Enable
1– Local temp conversion enabled
0– Local temp conversion disabled