For this application, the design requirements are as follows:
- Charging and discharging current
for single-cell battery of up to ±100A
- Sense resistor RSENSE of 200μΩ, equal
to VSENSE of ±20mV
- Maximum common-mode voltage of
VBAT at 4.2V
- Bipolar output voltage of ±2.5V