Calculate the inductor Volt × microsecond constant E × T (V × μs) from Equation 4.

where
Calculate the inductor Volt × microsecond constant (E × T) with Equation 5.

Use the E × T value from the previous formula and match it with the E × T number on the vertical axis of the inductor value selection guide in Figure 7-7. E × T = 21.6 (V × μs).
On the horizontal axis, select the maximum load current (ILOAD(max) = 1 A).
Identify the inductance region intersected by the E × T value and the maximum load current value. Each region is identified by an inductance value and an inductor code (LXX). From the inductor value selection guide shown in Figure 7-7, the inductance region intersected by the 21.6 (V × μs) horizontal line and the 1-A vertical line is
68 μH, and the inductor code is L30.
Select an appropriate inductor from the four manufacturer's part numbers listed in Table 7-2. For information on the different types of inductors, see the inductor selection in the fixed output voltage design procedure. From Table 7-2, locate line L30, and select an inductor part number from the list of manufacturers' part numbers.