SNAS851A December 2023 – May 2025 LMX1906-SP
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
The four main clocks must be the same frequency, but this frequency can be bypassed, multiplied, or divided. This is determined by the CLK_MUX word.
| CLK_MUX | OPTION | VALUES SUPPORTED | |
|---|---|---|---|
| 0 | Buffer Mode | ÷1 (bypass) | |
| 1 | Divider Mode | ÷2, 3, 4, 5, and 7 | |
| 2 | Multiplier Mode | x2, x3, x4 | |