SLOSE73A June 2021 – November 2021 TAS6424E-Q1
PRODUCTION DATA
The Channel State Reporting register is shown in Figure 9-26 and described in Table 9-22.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
CH1 STATE REPORT | CH2 STATE REPORT | CH3 STATE REPORT | CH4 STATE REPORT | ||||
R-01 | R-01 | R-01 | R-01 |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7–6 | CH1 STATE REPORT | R | 01 | 00: PLAY 01: Hi-Z 10: MUTE 11: DC load diagnostics |
5–4 | CH2 STATE REPORT | R | 01 | 00: PLAY 01: Hi-Z 10: MUTE 11: DC load diagnostics |
3–2 | CH3 STATE REPORT | R | 01 | 00: PLAY 01: Hi-Z 10: MUTE 11: DC load diagnostics |
1–0 | CH4 STATE REPORT | R | 01 | 00: PLAY 01: Hi-Z 10: MUTE 11: DC load diagnostics |