SBOSA15B September   2022  – January 2025 TMP1827

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Description (cont.)
  6. Device Comparison
  7. Pin Configuration and Functions
  8. Specifications
    1. 7.1  Absolute Maximum Ratings
    2. 7.2  ESD Ratings
    3. 7.3  Recommended Operating Conditions
    4. 7.4  Thermal Information
    5. 7.5  Electrical Characteristics
    6. 7.6  1-Wire® Interface Timing
    7. 7.7  Security Engine Characteristics
    8. 7.8  EEPROM Characteristics
    9. 7.9  Timing Diagrams
    10. 7.10 Typical Characteristics
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1  Power Up
      2. 8.3.2  Power Mode Switch
      3. 8.3.3  Bus Pullup Resistor
      4. 8.3.4  Temperature Results
      5. 8.3.5  Temperature Offset
      6. 8.3.6  Temperature Alert
      7. 8.3.7  Standard Device Address
        1. 8.3.7.1 Unique 64-Bit Device Address and ID
      8. 8.3.8  Flexible Device Address
        1. 8.3.8.1 Non-Volatile Short Address
        2. 8.3.8.2 IO Hardware Address
        3. 8.3.8.3 Resistor Address
        4. 8.3.8.4 Combined IO and Resistor Address
      9. 8.3.9  CRC Generation
      10. 8.3.10 Functional Register Map
      11. 8.3.11 User Memory Map
      12. 8.3.12 SHA-256-HMAC Authentication Block
      13. 8.3.13 Bit Communication
        1. 8.3.13.1 Host Write, Device Read
        2. 8.3.13.2 Host Read, Device Write
      14. 8.3.14 Bus Speed
      15. 8.3.15 NIST Traceability
    4. 8.4 Device Functional Modes
      1. 8.4.1 Conversion Modes
        1. 8.4.1.1 Basic One-Shot Conversion Mode
        2. 8.4.1.2 Auto Conversion Mode
        3. 8.4.1.3 Stacked Conversion Mode
        4. 8.4.1.4 Continuous Conversion Mode
      2. 8.4.2 Alert Function
        1. 8.4.2.1 Alert Mode
        2. 8.4.2.2 Comparator Mode
      3. 8.4.3 1-Wire® Interface Communication
        1. 8.4.3.1 Bus Reset Phase
        2. 8.4.3.2 Address Phase
          1. 8.4.3.2.1 READADDR (33h)
          2. 8.4.3.2.2 MATCHADDR (55h)
          3. 8.4.3.2.3 SEARCHADDR (F0h)
          4. 8.4.3.2.4 ALERTSEARCH (ECh)
          5. 8.4.3.2.5 SKIPADDR (CCh)
          6. 8.4.3.2.6 OVD SKIPADDR (3Ch)
          7. 8.4.3.2.7 OVD MATCHADDR (69h)
          8. 8.4.3.2.8 FLEXADDR (0Fh)
        3. 8.4.3.3 Function Phase
          1. 8.4.3.3.1  CONVERTTEMP (44h)
          2. 8.4.3.3.2  WRITE SCRATCHPAD-1 (4Eh)
          3. 8.4.3.3.3  READ SCRATCHPAD-1 (BEh)
          4. 8.4.3.3.4  COPY SCRATCHPAD-1 (48h)
          5. 8.4.3.3.5  WRITE SCRATCHPAD-2 (0Fh)
          6. 8.4.3.3.6  READ SCRATCHPAD-2 (AAh)
          7. 8.4.3.3.7  COPY SCRATCHPAD-2 (55h)
          8. 8.4.3.3.8  READ EEPROM (F0h)
          9. 8.4.3.3.9  GPIO WRITE (A5h)
          10. 8.4.3.3.10 GPIO READ (F5h)
      4. 8.4.4 NVM Operations
        1. 8.4.4.1 Programming User Data
        2. 8.4.4.2 Register and Memory Protection
          1. 8.4.4.2.1 Scratchpad-1 Register Protection
          2. 8.4.4.2.2 User Memory Protection
    5. 8.5 Programming
      1. 8.5.1 Single Device Temperature Conversion and Read
      2. 8.5.2 Multiple Device Temperature Conversion and Read
      3. 8.5.3 Register Scratchpad-1 Update and Commit
      4. 8.5.4 Single Device EEPROM Programming and Verify
      5. 8.5.5 Single Device EEPROM Page Lock Operation
      6. 8.5.6 Multiple Device IO Read
      7. 8.5.7 Multiple Device IO Write
    6. 8.6 Register Map
      1. 8.6.1  Temperature Result LSB Register (Scratchpad-1 offset = 00h) [reset = 00h]
      2. 8.6.2  Temperature Result MSB Register (Scratchpad-1 offset = 01h) [reset = 00h]
      3. 8.6.3  Status Register (Scratchpad-1 offset = 02h) [reset = 3Ch]
      4. 8.6.4  Device Configuration-1 Register (Scratchpad-1 offset = 04h) [reset = 70h]
      5. 8.6.5  Device Configuration-2 Register (Scratchpad-1 offset = 05h) [reset = 80h]
      6. 8.6.6  Short Address Register (Scratchpad-1 offset = 06h) [reset = 00h]
      7. 8.6.7  Temperature Alert Low LSB Register (Scratchpad-1 offset = 08h) [reset = 00h]
      8. 8.6.8  Temperature Alert Low MSB Register (Scratchpad-1 offset = 09h) [reset = 00h]
      9. 8.6.9  Temperature Alert High LSB Register (Scratchpad-1 offset = 0Ah) [reset = F0h]
      10. 8.6.10 Temperature Alert High MSB Register (Scratchpad-1 offset = 0Bh) [reset = 07h]
      11. 8.6.11 Temperature Offset LSB Register (Scratchpad-1 offset = 0Ch) [reset = 00h]
      12. 8.6.12 Temperature Offset MSB Register (Scratchpad-1 offset = 0Dh) [reset = 00h]
      13. 8.6.13 IO Read Register [reset = F0h]
      14. 8.6.14 IO Configuration Register [reset = 00h]
  10. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Applications
      1. 9.2.1 Bus Powered Application
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
      2. 9.2.2 Supply Powered Application
        1. 9.2.2.1 Design Requirements
        2. 9.2.2.2 Detailed Design Procedure
      3. 9.2.3 UART Interface for Communication
        1. 9.2.3.1 Design Requirements
        2. 9.2.3.2 Detailed Design Procedure
    3. 9.3 Power Supply Recommendations
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
      2. 9.4.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Documentation Support
      1. 10.1.1 Related Documentation
    2. 10.2 Receiving Notification of Documentation Updates
    3. 10.3 Support Resources
    4. 10.4 Trademarks
    5. 10.5 Electrostatic Discharge Caution
    6. 10.6 Glossary
  12. 11Revision History
  13. 12Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Continuous Conversion Mode

The continuous conversion mode is applicable only in VDD powered mode of operation for the device. This mode can be enabled by writing a value other than '000b' to CONV_MODE_SEL bits in the device configuration-1 register. As shown in Figure 8-16, the device can perform periodic conversions at the interval programmed by the host and updates the temperature result register when continuous conversion mode is enabled. The device also performs the alert threshold check and sets the flags and alert pin, if configured accordingly. When in continuous conversion mode, the CONVERTTEMP function has no effect on the temperature conversion request. The application can at any time change the rate of conversion or put the device back into one-shot conversion mode, and this takes effect only after the current conversion is complete.

TMP1827 Continuous Conversion ModeFigure 8-16 Continuous Conversion Mode

If due to any reason, the VDD supply fails without the device going through a brownout and causes the device to move to bus powered mode of operation, the conversion mode automatically reverts to the setting in the configuration EEPROM.