SLVSG51A April 2021 – February 2022 TPS23882B
PRODUCTION DATA
COMMAND = 1Bh with 1 Data Byte, Read/Write
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
MFR ID | ICV | ||||||
R/W-0 | R/W-1 | R/W-0 | R/W-1 | R/W-0 | R/W-1 | R/W-0 | R/W-1 |
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7–3 | MFR ID | R/W | 01010b | Manufacture Identification number (0101,0) |
2–0 | ICV | R/W | 101b | IC version number (011) |