SLVSHM3 November   2026 TPS2HCS05-Q1

PRODUCTION DATA  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Device Comparison Table
  6. 5 Pin Configuration and Functions
    1. 5.1 Package
    2. 5.2 Pinout A-version
    3. 5.3 Version B Package
    4. 5.4 Pinout B-version
  7. 6 Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 SPI Timing Requirements
    7. 6.7 Switching Characteristics
    8. 6.8 Typical Characteristics
  8. 7 Parameter Measurement Information
  9. 8 Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Device Functional Modes
      1. 8.3.1  State Diagram
      2. 8.3.2  Output Control
        1. 8.3.2.1 Output Control - Version A
        2. 8.3.2.2 Pin 5 Functions (DI or OUT_DIS) - Version A
        3. 8.3.2.3 Output Control - Version B
      3. 8.3.3  Output Disable Function (OUT_DIS)
      4. 8.3.4  SPI Mode Operation
        1. 8.3.4.1 SPI
        2. 8.3.4.2 Chip Select (CS or nCS)
        3. 8.3.4.3 System Clock
        4. 8.3.4.4 Serial Data In (SDI) and Serial Data Out (SDO)
        5. 8.3.4.5 CRC Error Detection and Checking of Clocks
        6. 8.3.4.6 SPI Frame Format
        7. 8.3.4.7 GLOBAL_FAULT_TYPE [15:8] Bits
        8. 8.3.4.8 SPI Watchdog Function
        9. 8.3.4.9 SPI Watchdog Operation - TPS2HCS05A-Q1
      5. 8.3.5  Fault Reporting
      6. 8.3.6  SLEEP
      7. 8.3.7  CONFIG/ACTIVE
      8. 8.3.8  LIMP_HOME State (Version A Only)
        1. 8.3.8.1 LIMP HOME State Exceptions
      9. 8.3.9  Battery Supply Input (VBB) Under-Voltage
        1. 8.3.9.1 VBB During Short-to-Ground
      10. 8.3.10 LOW POWER MODE (LPM) States
        1. 8.3.10.1 MANUAL_LPM State
          1. 8.3.10.1.1 System Wakeup from MANUAL_LPM
          2. 8.3.10.1.2 Automatic Exit from MANUAL_LPM
        2. 8.3.10.2 AUTO_LPM State
          1. 8.3.10.2.1 System Wakeup from AUTO_LPM
          2. 8.3.10.2.2 Automatic Exit from AUTO_LPM
    4. 8.4 Feature Description
      1. 8.4.1 Protection Mechanisms
        1. 8.4.1.1 Overcurrent Protection
          1. 8.4.1.1.1 Inrush Period - Overcurrent Protection
            1. 8.4.1.1.1.1 No Capacitive Charging - CAP_CHRG_CHx [1:0] = 00
            2. 8.4.1.1.1.2 Current Limit Regulation Capacitive Charging Mode - CAP_CHRG_CHx [1:0] = 10
          2. 8.4.1.1.2 Overcurrent Protection - Steady State Operation
          3. 8.4.1.1.3 Programmable Fuse Protection
          4. 8.4.1.1.4 Immediate Shutdown Overcurrent Protection (IOCP)
          5. 8.4.1.1.5 Auto retry and latch-off behavior
            1. 8.4.1.1.5.1 Auto retry behavior - No capacitive charging mode (CAP_CHRG_CHx = 00)
            2. 8.4.1.1.5.2 Latch-off Behavior - No Capacitive Charging Mode (CAP_CHRG_CHx = 00)
            3. 8.4.1.1.5.3 Auto Retry Behavior - Current Limit Regulation Charging Mode (CAP_CHRG_CHx = 10)
            4. 8.4.1.1.5.4 Latch-off Behavior - Current Limit Regulation Capactive Charging Mode (CAP_CHRG_CHx = 10)
        2. 8.4.1.2 Thermal Shutdown
          1. 8.4.1.2.1 Relative Thermal Shutdown (TREL)
          2. 8.4.1.2.2 Absolute Thermal Shutdown (TABS)
        3. 8.4.1.3 Reverse Battery
      2. 8.4.2 Diagnostic Mechanisms
        1. 8.4.2.1 Integrated ADC
        2. 8.4.2.2 Digital Current Sense Output
        3. 8.4.2.3 Output Voltage Measurement
        4. 8.4.2.4 MOSFET Temperature Measurement
        5. 8.4.2.5 Drain-to-Source Voltage (VDS) Measurement
        6. 8.4.2.6 VBB Voltage Measurement
        7. 8.4.2.7 VOUT Short-to-Battery and Open-Load
          1. 8.4.2.7.1 Measurement with Channel Output (FET) Enabled
          2. 8.4.2.7.2 Detection with Channel Output Disabled
            1. 8.4.2.7.2.1 Off-State Open Load Detection
            2. 8.4.2.7.2.2 Off-State Short-to-Battery Detection
            3. 8.4.2.7.2.3 Distinguishing Between Open Load and Short-to-Battery Faults
      3. 8.4.3 EEPROM Overview
        1. 8.4.3.1 EEPROM Programming Procedure
        2. 8.4.3.2 Customer Defined Programmable Registers
  10. 9 TPS2HCS05-Q1 Registers
  11. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedure
        1. 10.2.2.1 Thermal Considerations
        2. 10.2.2.2 Configuring the Capacitive Charging Mode
      3. 10.2.3 Application Curves
    3. 10.3 Power Supply Recommendations
    4. 10.4 Layout
      1. 10.4.1 Layout Guidelines
      2. 10.4.2 Layout Example
  12. 11Device and Documentation Support
    1. 11.1 Device Support
      1. 11.1.1 Third-Party Products Disclaimer
    2. 11.2 Support Resources
    3. 11.3 Trademarks
    4. 11.4 Electrostatic Discharge Caution
    5. 11.5 Glossary
  13. 12Revision History
  14. 13Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

AUTO_LPM State

The AUTO_LPM state provides a mode where the device can automatically transition to a low IQ state while keeping the channels on, if desired, and protected through short-circuit protection. Depending on the device version used, to enter the AUTO_LPM state the AUTO_LPM_ENTRY bit in the DEV_CONFIG register must be set to 1 and the following conditions need to be met for at least tSTBY_LPM_AUTO:

  • Version A
    • In active or config state with no channel state changes through CHx_ON bits
    • Enabled channels are not in the inrush period
    • All ADC diagnostics (VSNS, VBBSNS, TSNS, and VDS_SNS) are disabled except ISNS
    • OL_ON_EN_CHx = 0
    • IOUT < IENTRY_LPM_AUTO for enabled channels
    • AUTO_LPM_EXIT_CHx bits must both be set to 0
    • THERMAL_WRN_CHx = 0
    • Watchdog timer is disabled (WD_EN = 0)
    • No faults exist on the device
  • Version B
    • In active or config state with no channel state changes through DIx pins
    • Enabled channels are not in the inrush period
    • All ADC diagnostics (VSNS, VBBSNS, TSNS, and VDS_SNS) are disabled except ISNS
    • OL_ON_EN_CHx = 0
    • IOUT < IENTRY_LPM_AUTO for enabled channels
    • AUTO_LPM_EXIT_CHx bits must both be set to 0
    • THERMAL_WRN_CHx = 0
    • Watchdog timer is disabled (WD_EN = 0)
    • No faults exist on the device

Once the conditions are met, the device updates the LPM_STATUS bit in the SDO frame/GLOBAL_FAULT_TYPE register and the LPM_STATUS_1 bit in the GLOBAL_FAULT_TYPE register before entering the AUTO_LPM state to alert the system that device has transitioned to AUTO_LPM. The device enters AUTO_LPM state in tLPM_ENTRY.

Note:

Note: If the device is configured to the MANUAL_LPM state before setting the AUTO_LPM_ENTRY bit to 1, additional SPI commands are required to enable Auto LPM Entry. To specify a safe transition from Manual LPM to Auto LPM, if the device exits Manual LPM due to a Load Step or Short Circuit event, the MANUAL_LPM bit must be set to 1 and then reset to 0. After this entry and exit from the Manual LPM state is complete, the AUTO_LPM_ENTRY bit can be set to 1, and the device enters Auto LPM once all conditions are met.

In the AUTO_LPM state, the larger internal FET is used to allow for larger load steps. The RON for the larger internal FET is defined by the RON,LPM_AUTO in the electrical characteristics section. The IQ in AUTO_LPM is higher compared to the small FET operation in MANUAL_LPM state and roughly the same as the MANUAL_LPM state with the larger FET operation. In AUTO_LPM, the entry threshold is specified by IENTRY_LPM_AUTO and the exit threshold is specified by IEXIT_LPM_AUTO.