SLVSHM3 November   2026 TPS2HCS05-Q1

PRODUCTION DATA  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Device Comparison Table
  6. 5 Pin Configuration and Functions
    1. 5.1 Package
    2. 5.2 Pinout A-version
    3. 5.3 Version B Package
    4. 5.4 Pinout B-version
  7. 6 Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 SPI Timing Requirements
    7. 6.7 Switching Characteristics
    8. 6.8 Typical Characteristics
  8. 7 Parameter Measurement Information
  9. 8 Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Device Functional Modes
      1. 8.3.1  State Diagram
      2. 8.3.2  Output Control
        1. 8.3.2.1 Output Control - Version A
        2. 8.3.2.2 Pin 5 Functions (DI or OUT_DIS) - Version A
        3. 8.3.2.3 Output Control - Version B
      3. 8.3.3  Output Disable Function (OUT_DIS)
      4. 8.3.4  SPI Mode Operation
        1. 8.3.4.1 SPI
        2. 8.3.4.2 Chip Select (CS or nCS)
        3. 8.3.4.3 System Clock
        4. 8.3.4.4 Serial Data In (SDI) and Serial Data Out (SDO)
        5. 8.3.4.5 CRC Error Detection and Checking of Clocks
        6. 8.3.4.6 SPI Frame Format
        7. 8.3.4.7 GLOBAL_FAULT_TYPE [15:8] Bits
        8. 8.3.4.8 SPI Watchdog Function
        9. 8.3.4.9 SPI Watchdog Operation - TPS2HCS05A-Q1
      5. 8.3.5  Fault Reporting
      6. 8.3.6  SLEEP
      7. 8.3.7  CONFIG/ACTIVE
      8. 8.3.8  LIMP_HOME State (Version A Only)
        1. 8.3.8.1 LIMP HOME State Exceptions
      9. 8.3.9  Battery Supply Input (VBB) Under-Voltage
        1. 8.3.9.1 VBB During Short-to-Ground
      10. 8.3.10 LOW POWER MODE (LPM) States
        1. 8.3.10.1 MANUAL_LPM State
          1. 8.3.10.1.1 System Wakeup from MANUAL_LPM
          2. 8.3.10.1.2 Automatic Exit from MANUAL_LPM
        2. 8.3.10.2 AUTO_LPM State
          1. 8.3.10.2.1 System Wakeup from AUTO_LPM
          2. 8.3.10.2.2 Automatic Exit from AUTO_LPM
    4. 8.4 Feature Description
      1. 8.4.1 Protection Mechanisms
        1. 8.4.1.1 Overcurrent Protection
          1. 8.4.1.1.1 Inrush Period - Overcurrent Protection
            1. 8.4.1.1.1.1 No Capacitive Charging - CAP_CHRG_CHx [1:0] = 00
            2. 8.4.1.1.1.2 Current Limit Regulation Capacitive Charging Mode - CAP_CHRG_CHx [1:0] = 10
          2. 8.4.1.1.2 Overcurrent Protection - Steady State Operation
          3. 8.4.1.1.3 Programmable Fuse Protection
          4. 8.4.1.1.4 Immediate Shutdown Overcurrent Protection (IOCP)
          5. 8.4.1.1.5 Auto retry and latch-off behavior
            1. 8.4.1.1.5.1 Auto retry behavior - No capacitive charging mode (CAP_CHRG_CHx = 00)
            2. 8.4.1.1.5.2 Latch-off Behavior - No Capacitive Charging Mode (CAP_CHRG_CHx = 00)
            3. 8.4.1.1.5.3 Auto Retry Behavior - Current Limit Regulation Charging Mode (CAP_CHRG_CHx = 10)
            4. 8.4.1.1.5.4 Latch-off Behavior - Current Limit Regulation Capactive Charging Mode (CAP_CHRG_CHx = 10)
        2. 8.4.1.2 Thermal Shutdown
          1. 8.4.1.2.1 Relative Thermal Shutdown (TREL)
          2. 8.4.1.2.2 Absolute Thermal Shutdown (TABS)
        3. 8.4.1.3 Reverse Battery
      2. 8.4.2 Diagnostic Mechanisms
        1. 8.4.2.1 Integrated ADC
        2. 8.4.2.2 Digital Current Sense Output
        3. 8.4.2.3 Output Voltage Measurement
        4. 8.4.2.4 MOSFET Temperature Measurement
        5. 8.4.2.5 Drain-to-Source Voltage (VDS) Measurement
        6. 8.4.2.6 VBB Voltage Measurement
        7. 8.4.2.7 VOUT Short-to-Battery and Open-Load
          1. 8.4.2.7.1 Measurement with Channel Output (FET) Enabled
          2. 8.4.2.7.2 Detection with Channel Output Disabled
            1. 8.4.2.7.2.1 Off-State Open Load Detection
            2. 8.4.2.7.2.2 Off-State Short-to-Battery Detection
            3. 8.4.2.7.2.3 Distinguishing Between Open Load and Short-to-Battery Faults
      3. 8.4.3 EEPROM Overview
        1. 8.4.3.1 EEPROM Programming Procedure
        2. 8.4.3.2 Customer Defined Programmable Registers
  10. 9 TPS2HCS05-Q1 Registers
  11. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedure
        1. 10.2.2.1 Thermal Considerations
        2. 10.2.2.2 Configuring the Capacitive Charging Mode
      3. 10.2.3 Application Curves
    3. 10.3 Power Supply Recommendations
    4. 10.4 Layout
      1. 10.4.1 Layout Guidelines
      2. 10.4.2 Layout Example
  12. 11Device and Documentation Support
    1. 11.1 Device Support
      1. 11.1.1 Third-Party Products Disclaimer
    2. 11.2 Support Resources
    3. 11.3 Trademarks
    4. 11.4 Electrostatic Discharge Caution
    5. 11.5 Glossary
  13. 12Revision History
  14. 13Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
  • PWC|18
Thermal pad, mechanical data (Package|Pins)
Orderable Information
Automatic Exit from AUTO_LPM

When in AUTO_LPM state, the device wakes up and changes the LPM_STATUS bit to 0 when there is a load current increase beyond the IEXIT_LPM_AUTO threshold. The LPM_STATUS_1 bit in the GLOBAL_FAULT_TYPE register is set to 1 when in AUTO_LPM state and is read clear which enables the system to tell if the device had transitioned to the AUTO_LPM state since the GLOBAL_FAULT_TYPE register is last read. An ECU load current demand increase above the IEXIT_LPM_AUTO threshold activates the transition to the ACTIVE state. Note, in this load increase scenario the device does not pull the FLT / WAKE_SIG low.

If there is a larger ECU load current demand increase or output short circuit above the ISCP_LPM_AUTO, the device turns off the internal FET for that channel and retries in tRETRY,INT with IOCP set as the overcurrent protection threshold. In this scenario, the device pulls the FLT / WAKE_SIG pin low when there is a load current increase beyond the ISCP_LPM_AUTO threshold. The device registers a fault as over-current protection fault only if the overcurrent is also confirmed in the ACTIVE state.

Depending on the load step magnitude, the device transitions to the ACTIVE state in different ways. Figure 8-22, Figure 8-23, and Figure 8-24 showcase how the device responds to different load step magnitudes.

TPS2HCS05-Q1 Load Increase Above IEXIT_LPM_AUTO and Below ISCP_LPM_AUTO in AUTO_LPM StateFigure 8-22 Load Increase Above IEXIT_LPM_AUTO and Below ISCP_LPM_AUTO in AUTO_LPM State
TPS2HCS05-Q1 Load Increase Above ISCP_LPM_AUTO and Below IOCP in AUTO_LPM StateFigure 8-23 Load Increase Above ISCP_LPM_AUTO and Below IOCP in AUTO_LPM State
TPS2HCS05-Q1 Load Increase Above IOCP in AUTO_LPM StateFigure 8-24 Load Increase Above IOCP in AUTO_LPM State