JAJSNC5 april   2023 LM5171-Q1

ADVANCE INFORMATION  

  1. 特長
  2. アプリケーション
  3. 概要
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Timing Requirements
    7. 6.7 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1  Bias Supplies and Voltage Reference (VCC, VDD, and VREF)
      2. 7.3.2  Undervoltage Lockout (UVLO) and Controller Enable or Disable
      3. 7.3.3  High Voltage Inputs (HV1, HV2)
      4. 7.3.4  Current Sense Amplifier
      5. 7.3.5  Control Commands
        1. 7.3.5.1 Channel Enable Commands (EN1, EN2)
        2. 7.3.5.2 Direction Command (DIR1 and DIR2)
        3. 7.3.5.3 Channel Current Setting Commands (ISET1 and ISET2)
      6. 7.3.6  Channel Current Monitor (IMON1, IMON2)
        1. 7.3.6.1 Individual Channel Current Monitor
        2. 7.3.6.2 Multiphase Total Current Monitoring
      7. 7.3.7  Cycle-by-Cycle Peak Current Limit (IPK)
      8. 7.3.8  Inner Current Loop Error Amplifier
      9. 7.3.9  Outer Voltage Loop Error Amplifier
      10. 7.3.10 Soft Start, Diode Emulation, and Forced PWM Control (SS/DEM1 and SS/DEM2)
        1. 7.3.10.1 Soft-Start Control by the SS/DEM Pins
        2. 7.3.10.2 DEM Programming
        3. 7.3.10.3 FPWM Programming and Dynamic FPWM and DEM Change
        4. 7.3.10.4 SS Pin as the Restart Timer
      11. 7.3.11 Gate Drive Outputs, Dead Time Programming and Adaptive Dead Time (HO1, HO2, LO1, LO2, DT/SD)
      12. 7.3.12 Emergent Latched Shutdown (DT/SD)
      13. 7.3.13 PWM Comparator
      14. 7.3.14 Oscillator (OSC)
      15. 7.3.15 Synchronization to an External Clock (SYNCI, SYNCO)
      16. 7.3.16 Overvoltage Protection (OVP)
      17. 7.3.17 Multiphase Configurations (SYNCO, OPT)
        1. 7.3.17.1 Multiphase in Star Configuration
        2. 7.3.17.2 Daisy-Chain Configurations for 2, 3, or 4 Phases parallel operations
        3. 7.3.17.3 Daisy-Chain configuration for 6 or 8 phases parallel operation
      18. 7.3.18 Thermal Shutdown
    4. 7.4 Programming
      1. 7.4.1 Dynamic Dead Time Adjustment
      2. 7.4.2 UVLO Programming
    5. 7.5 I2C Serial Interface
      1. 7.5.1 REGFIELD Registers
  8. Application and Implementation
    1. 8.1 Application Information
      1. 8.1.1 Small Signal Model
        1. 8.1.1.1 Current Loop Small Signal Model
        2. 8.1.1.2 Current Loop Compensation
        3. 8.1.1.3 Voltage Loop Small Signal Model
        4. 8.1.1.4 Voltage Loop Compensation
    2. 8.2 Typical Application
      1. 8.2.1 60-A, Dual-Phase, 48-V to 12-V Bidirectional Converter
        1. 8.2.1.1 Design Requirements
        2. 8.2.1.2 Detailed Design Procedure
          1. 8.2.1.2.1  Determining the Duty Cycle
          2. 8.2.1.2.2  Oscillator Programming
          3. 8.2.1.2.3  Power Inductor, RMS and Peak Currents
          4. 8.2.1.2.4  Current Sense (RCS)
          5. 8.2.1.2.5  Current Setting Limits (ISETx)
          6. 8.2.1.2.6  Peak Current Limit
          7. 8.2.1.2.7  Power MOSFETS
          8. 8.2.1.2.8  Bias Supply
          9. 8.2.1.2.9  Boot Strap
          10. 8.2.1.2.10 OVP
          11. 8.2.1.2.11 Dead Time
          12. 8.2.1.2.12 Channel Current Monitor (IMONx)
          13. 8.2.1.2.13 UVLO Pin Usage
          14. 8.2.1.2.14 HVx Pin Configuration
          15. 8.2.1.2.15 Loop Compensation
          16. 8.2.1.2.16 Soft Start
          17. 8.2.1.2.17 PWM to ISET Pins
        3. 8.2.1.3 Application Curves
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Examples
  9. Device and Documentation Support
    1. 9.1 Device Support
      1. 9.1.1 Development Support
    2. 9.2 ドキュメントの更新通知を受け取る方法
    3. 9.3 サポート・リソース
    4. 9.4 Trademarks
    5. 9.5 静電気放電に関する注意事項
    6. 9.6 用語集
  10. 10Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Recommended Operating Conditions

Over the recommended operating junction temperature range of –40°C to 150°C (unless otherwise specified)(1)
MIN NOM MAX UNIT
HV-Port (HV1, HV2) Buck Mode 3 80 V
HV-Port (HV1, HV2) Boost Mode 3 80 V
LV-Port Buck Mode 0 75 V
LV-Port Boost Mode 1 75 V
VCC Applicable External Voltage to VCC Pin 9.5 12 V
TJ Operating Junction Temperature(2) –40 150 °C
FOSC Oscillator Frequency 50 1000 kHz
FEX_CLK Synchronization to External Clock Frequency (Minimal 50kHz) 0.8x FOSC 1.2x FOSC kHz
FEX_CLK SYNCI Pulse 50 0.8/ FOSC ns
tDT Programmable Dead Time Range 15 200 ns
Operating Ratings are conditions under the device is intended to be functional. For specifications and test conditions, see Section 6.5.
High junction temperatures degrade operating lifetimes. Operating lifetime is de-rated for junction temperatures greater than 125°C.