SPRACP3C November   2019  – December 2021 AWR6843 , AWR6843AOP , IWR1443 , IWR1642 , IWR6443 , IWR6843 , IWR6843AOP

 

  1.   Trademarks
  2. 1Introduction
  3. 2Typical Certification Procedure
  4. 3Regulatory Compliance Overview
    1. 3.1 European Union Regulations - Radio Equipment directive (RED)
      1. 3.1.1 Efficient Use of the Radio Spectrum (EN 305 550)
      2. 3.1.2 RF Exposure Limit - EN 62311
      3. 3.1.3 Electrical Safety - EN 62368
      4. 3.1.4 ElectroMagnetic Compatibility (EMC) - EN 301 489-1
    2. 3.2 Federal Communications Commission (FCC)
      1. 3.2.1 End Equipment and FCC Clause
      2. 3.2.2 Fundamental Emmision levels
      3. 3.2.3 Spurious Emission
      4. 3.2.4 Frequency Stability
      5. 3.2.5 Radiation Exposure Requirement
      6. 3.2.6 FCC Waiver and Other Relevant Information
    3. 3.3 Applicable Terms and Equations
      1. 3.3.1 Duty Cycle Factor
      2. 3.3.2 Effective Isotropic Radiated Power (EIRP)
      3. 3.3.3 Friis Equation
      4. 3.3.4 Far-Field Boundary
  5. 4Tools and Setup
    1. 4.1 Hardware Setup
    2. 4.2 MMWAVESTUDIO
      1. 4.2.1 Running LUA Scripts
    3. 4.3 mmWave Visualizer
    4. 4.4 IWR6843ISK-ODS Test Case
  6. 5Common Issues and Resolutions
    1. 5.1 Peak Power
    2. 5.2 Occupied Bandwidth
    3. 5.3 Spurious Emissions
      1. 5.3.1 14.4-Ghz Harmonics
      2. 5.3.2 Suggested Resolution
        1. 5.3.2.1 Hardware Measures
        2. 5.3.2.2 Software Measures
    4. 5.4 Overshoot
    5. 5.5 Frequency Stability
      1. 5.5.1 Generating CW Signal
      2. 5.5.2 Frequency Stability Over Temperature and Voltage Range
  7. 6References
  8. 7Revision History

ElectroMagnetic Compatibility (EMC) - EN 301 489-1

The following criteria applies for the test per the standard for EMC emissions and immunity.

Table 3-4 EMC Emissions and Immunity Performance Criteria
CriterionDuring TestAfter Test
AOperate as intended. No loss of function. No unintentional responsesOperate as intended. No loss of function. No degradation of performance. No loss of stored data or user programmable functions.
BMay show loss of function. No unintentional responsesOperate as intended. Lost functions shall be self-recoverable. No degradation of performance. No loss of stored data or user programmable functions.

The following clauses under EN 301 489-1 are applicable to the TI IWR6843 / MMWAVEICBOOST Evaluation Module combo, since the equipment required DC power and is not a telecomunication equipment some of the tests do not apply. Users must determine which test is applicable to their end equipment.

Table 3-5 Clause 8 of EN 301 489-1 – Methods of Measurement and Limits for EMC Emissions Results
Environmental phenomenonVerdict
Enclosure of ancillary equipment measured on a standalone basis – Clause 8.2Ancillary equipment Class B limits given in EN 55032Pass
Ancillary equipment Radiated disturbance above 1 GHz at a measurement distance of 3 mPass
Ancillary equipment intended to be used in telecommunication centers only Class A limits given in EN 55032Not applicable
Ancillary equipment intended to be used in telecommunication centers only Radiated disturbance above 1 GHz at a measurement distance of 3 mNot applicable
DC power input/output ports – Clause 8.3Class B limits according to EN 55032Pass
Equipment intended to be used in telecommunication centers onlyNot applicable
AC mains power input/output ports – Clause 8.4Class B limits given in EN 55032Not applicable
Equipment intended to be used in telecommunication centers only Class A limits given in EN 55032Not applicable
Harmonic current emissions (AC mains input port)– Clause 8.5The appropriate requirements of EN 61000-3-2/A1 for harmonic current emission apply for equipment with an input current up to and including 16 A per phase. For equipment with an input current of greater than 16 A per phase EN 61000-3-12 applies.Not applicable
Voltage fluctuations and flicker (AC mains input port) – Clause 8.6The appropriate requirements of EN 61000-3-3 for voltage fluctuations and flicker apply for equipment with an input current up to and including 16 A per phase. For equipment with an input current of greater than 16 A per phase EN 61000-3-11 [13] applies.Not applicable
Telecommunication ports – Clause 8.7Class B limits given in EN 55032Not applicable
Equipment intended to be used in telecommunication centers only Class A limits given in EN 55032Not applicable
Table 3-6 Clause 9 of EN 301 489-1 Test Methods and Levels for Immunity Tests Results
Environmental phenomenonTest portBasic standardVerdict
Radio frequency electromagnetic field (80 MHz to 1000 MHz and 1000 MHz to 6000 MHz) – Clause 9.2EnclosureEN 61000-4-3Pass
Electrostatic discharge1 – Clause 9.3EnclosureEN 61000-4-2Pass
Fast transients, Common mode– Clause 9.4AC mains power portEN 61000-4-4Not applicable
Signal ports, telecommunication ports, control portsNot applicable
DC power portsPass
Radio frequency, common mode (0.15 MHz to 80 MHz) – Clause 9.5AC mains power portEN 61000-4-6Not applicable
Signal ports, telecommunication ports, control portsNot applicable
DC power portsPass
Transients and surges – Clause 9.612 V and 24 V DC supply voltage input ports of mobile radio and ancillary equipment, which are also intended for mobile use in vehicles.ISO 7637-2Not applicable
Voltage dips and interruptions – Clause 9.7AC mains power portEN 61000-4-11Not applicable
Surges line to line and line to ground – Clause 9.8AC mains power portEN 61000-4-5Not applicable
Telecommunication portsNot applicable