DLPU057A March 2018 – April 2022 DLP3030-Q1
This is the data response for a valid request to read the Command List Info.
For types 1, 2, and 4:
| Byte | Description |
| 1 | Response Byte (01h) |
| 2 | Length (31h) |
| 3 - 30 | Command List Name (ASCII values of each character) |
| 31 | Checksum (Sum of bytes 1 to 30) |
For type 3:
| Byte | Description |
| 1 | Response Byte (01h) |
| 2 | Length (0Bh) |
| 3 | Horizontal Resolution (lsb) |
| 4 | Horizontal Resolution (msb) |
| 5 | Vertical Resolution (lsb) |
| 6 | Vertical Resolution (msb) |
| 7 | Frequency |
| 8 | Output Horizontal Resolution (lsb) |
| 9 | Output Horizontal Resolution (msb) |
| 10 | Output Vertical Resolution (lsb) |
| 11 | Output Vertical Resolution (msb) |
| 12 | Checksum (Sum of bytes 1 to 11) |
Note: Any invalid type (less than 1 or greater than 3 + Number of Generic Types) will cause the command to fail and flag a ‘data out of range’ error.