DLPU057A March 2018 – April 2022 DLP3030-Q1
This is the data response for a request to read the Low Pass Filter Constants.
| Byte | Description |
| 1 | Response Byte (01h) |
| 2 | Length (08h) |
| 3 | Low Pass Filter Strength (lsb) |
| 4 | Low Pass Filter Strength |
| 5 | Low Pass Filter Strength |
| 6 | Low Pass Filter Strength (msb) |
| 7 | Low Pass Filter Quantization Step (lsb) |
| 8 | Low Pass Filter Quantization Step |
| 9 | Low Pass Filter Quantization Step |
| 10 | Low Pass Filter Quantization Step (msb) |
| 11 | Checksum (Sum of bytes 1 to 10) |
Note: The Filter Coefficients are floating point numbers. Please refer to Section 5 for the read and write format for such numbers.