SBASAI5E May   2023  – April 2026 TMAG5253

PRODUCTION DATA  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Device Comparison
  6. 5 Pin Configuration and Functions
  7. 6 Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Electrical Characteristics (Bipolar, TMAG5253BAx)
    6. 6.6  Magnetic Characteristics (Bipolar, TMAG5253BAx)
    7. 6.7  Electrical Characteristics (Unipolar, TMAG5253UAx)
    8. 6.8  Magnetic Characteristics (Unipolar, TMAG5253UAx)
    9. 6.9  Typical Characteristics (Bipolar, TMAG5253BAx)
    10. 6.10 Typical Characteristics (Unipolar, TMAG5253UAx)
  8. 7 Parameter Measurement Information
    1. 7.1 Sensitivity Linearity
    2. 7.2 Ratiometric Architecture
    3. 7.3 Sensitivity Temperature Compensation
    4. 7.4 Quiescent Voltage Temperature Drift
    5. 7.5 Power-On Time
  9. 8 Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Magnetic Flux Direction
      2. 8.3.2 Hall Element Location
      3. 8.3.3 Magnetic Response
    4. 8.4 Device Functional Modes
  10. 9 Application and Implementation
    1. 9.1 Application Information
      1. 9.1.1 Selecting the Sensitivity Option
      2. 9.1.2 Temperature Compensation for Magnets
      3. 9.1.3 Adding a Low-Pass Filter
      4. 9.1.4 Designing With Multiple Sensors
      5. 9.1.5 Duty-Cycled, Low-Power Design
    2. 9.2 Typical Applications
      1. 9.2.1 Slide-By Displacement Sensing
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
        3. 9.2.1.3 Application Curves
      2. 9.2.2 Head-On Displacement Sensing
        1. 9.2.2.1 Design Requirements
        2. 9.2.2.2 Detailed Design Procedure
        3. 9.2.2.3 Application Curve
      3. 9.2.3 Remote-Sensing Applications
    3. 9.3 Best Design Practices
    4. 9.4 Power Supply Recommendations
    5. 9.5 Layout
      1. 9.5.1 Layout Guidelines
      2. 9.5.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Documentation Support
      1. 10.1.1 Related Documentation
    2. 10.2 Receiving Notification of Documentation Updates
    3. 10.3 Support Resources
    4. 10.4 Trademarks
    5. 10.5 Electrostatic Discharge Caution
    6. 10.6 Glossary
  12. 11Revision History
  13. 12Mechanical, Packaging, and Orderable Information

Magnetic Characteristics (Unipolar, TMAG5253UAx)

For VCC = 1.65V to 3.6V, over operating free-air temperature range (unless otherwise noted). Typical specifications are at TA = 25°C and VCC = 3.3V (unless otherwise noted).
PARAMETER TEST CONDITIONS(1) MIN TYP MAX UNIT
VQ Quiescent voltage VCC = 3.3V,
B = 0mT,
TA = 25°C
Unipolar, UA2 0.11 0.2 0.32 V
Unipolar, UA5 0.11 0.2 0.32
VCC = 1.8V,
B = 0mT,
TA = 25°C
Unipolar, UA2 0.12 0.2 0.29
Unipolar, UA5 0.14 0.2 0.29
VQΔT Quiescent voltage temperature drift VCC = 3.3V,
B = 0mT
TA = 0°C to 85°C vs 25°C,
Unipolar, UA2
-50 50 mV
TA = -40°C to 125°C vs 25°C,
Unipolar, UA2 and UA5
-78 78
VCC = 1.8V,
B = 0mT
TA = 0°C to 85°C vs 25°C,
Unipolar, UA2
-30 30
TA = -40°C to 125°C vs 25°C,
Unipolar, UA2 and UA5
-78 78
VQΔL Quiescent voltage lifetime drift High-temperature operating stress for 1000 hours
VCC = 3.3V
10 mV
S Sensitivity VCC = 3.3V,
TA = 25°C
Unipolar, UA2 62 73 84 mV/mT
Unipolar, UA5 40.8 48 55.2
VCC = 1.8V,
TA = 25°C
Unipolar, UA2 29 35 41
Unipolar, UA5 21.0 24.7 28.4
BL Linear magnetic sensing range(2)(3) VCC = 3.3V,
TA = 25°C
Unipolar, UA2 39 mT
Unipolar, UA5 52
VCC = 1.8V,
TA = 25°C
Unipolar, UA2 39
Unipolar, UA5 52
VL Linear range of output voltage(3) Unipolar, UAx VQ VCC – 0.2 V
STC Sensitivity temperature coefficient(4) Unipolar, UAx TA = -40°C to 125°C vs 25°C 0.04 0.12 0.2 %/°C
SLE Sensitivity linearity error(3) VOUT is within VL ±0.1 ±0.55 %
SRE Sensitivity ratiometry error(5) TA = 25°C VCC = 3V - 3.6V,
With respect to VCC = 3.3V
-3 3 %
VCC = 1.65V - 1.9V,
With respect to VCC = 1.8V
-2 2
SΔL Sensitivity lifetime drift High-temperature operating stress for 1000 hours 0.5 %
BND Input-referred RMS noise density VCC = 3.3V
CLoad = 100pF
Unipolar, UA2 150 nT/√Hz
Unipolar, UA5 220
VCC = 1.8V
CLoad = 100pF
Unipolar, UA2 320
Unipolar, UA5 400
BN
Input-referred peak-to-peak noise

VCC = 3.3V
CLoad = 100pF
BW = 15kHz
BND × 6.6 × √fBW
Unipolar, UA2 0.12 mTPP
Unipolar, UA5 0.17
VCC = 1.8V
CLoad = 100pF
BW = 15kHz
BND × 6.6 × √fBW
Unipolar, UA2 0.26
Unipolar, UA5 0.35
VN Output-referred peak-to-peak noise VCC = 3.3V
BN × S
Unipolar, UA2 8.5 mVPP
Unipolar, UA5 9
VCC = 1.8V
BN × S
Unipolar, UA2 9
B is the applied magnetic flux density.
BL describes the minimum linear sensing range at 25°C taking into account the maximum VQ and Sensitivity tolerances.
Refer to the Sensitivity Linearity section.
STC describes the rate the device increases Sensitivity with temperature. For more information, see the Section 7.3.
Refer to the Ratiometric Architecture section