Follow the steps below to program the
TMAG3101EVM into an analog operating mode and view results.
- Verify the TMAG3101EVM is configured for
SWIFT operating mode as described in Section 2.3.
- Connect to and launch the GUI as
described in Section 3.2.1.3.2. When the TMAG3101EVM
first connects to the GUI, the firmware performs a read of the full TMAG3101-Q1 EEPROM
registers. This typically takes a few seconds to complete. When complete, the EEPROM
contents are shown on the Register tab of the GUI.
- In the Configuration tab, click the
Operating Mode drop-down box and select the "Analog Continuous Conversion" operating
mode.
- Configure the desired Magnetic
Configuration settings, as shown in Figure 3-20. Select the magnetic
channels to enable, angle calculation (if desired), and desired data output from the
device. Use the X, Y, and Z range drop-downs to configure the desired sensing range for
each axis. If desired, alter the polarity of any axis, enable different levels of
filtering or averaging, or alter the angle polarity.
- Configure the analog specific
configuration settings, as shown in Figure 3-21. Select the desired load
drive and enable or disable dynamic scaling on the analog output. For more information on
analog output configuration options, please see the TMAG3101-Q1 datasheet.
- Select "Program Device" and the GUI
programs the TMAG3101EVM according to the configuration and force the EVM into the analog
output mode using the SWIFT interface.

- To return the TMAG3101-Q1 to SWIFT
mode, select "SWIFT mode" from the "Operating Mode" drop-down list and press "Program
Device".
- To view the data output from the device,
go to the Results data tab. Select the desired result plots under the Results to
collect/show box in the Results Data tab, and select Collect Data to
begin collecting data.

- In analog mode, data can also be viewed in the "Analog Detailed
Results" tab. Select the appropriate ADC sensing option from the drop down--ADC121C021 for
the external ADC or the SCB internal ADC. Remember that these options are only valid
depending on which of resistors R5 and R6 are populated or depopulated on the board. This
displays the ADC reference voltage for the selection. Select "Start Collection" to see the
analog OUT voltage displayed on the meter, as well as the ADC range percentage used.