SBAU457 October   2026

 

  1.   1
  2.   Description
  3.   Get Started
  4.   Features
  5.   Applications
  6.   6
  7. 1Evaluation Module Overview
    1. 1.1 Introduction
    2. 1.2 Kit Contents
    3. 1.3 Specifications
    4. 1.4 Device Information
  8. 2Hardware
    1. 2.1 TMAG3101-Q1 EVM Components
    2. 2.2 SCB LEDs
    3. 2.3 Hardware Jumper J7 and Resistor Configurations for Different Operating Modes
  9. 3Software
    1. 3.1 Quick Start Setup
    2. 3.2 EVM Operation
      1. 3.2.1 Setup
        1. 3.2.1.1 Driver Installation
        2. 3.2.1.2 Firmware
          1. 3.2.1.2.1 Updating Firmware on SCB
        3. 3.2.1.3 GUI Setup and Usage
          1. 3.2.1.3.1 Initial Setup
          2. 3.2.1.3.2 GUI Operation
      2. 3.2.2 Rotate and Push Demo
      3. 3.2.3 SENT and Triggered SENT Operating Modes
      4. 3.2.4 Analog Operating Mode
      5. 3.2.5 PWM Operating Mode
      6. 3.2.6 Direct EVM Serial Communication
  10. 4Hardware Design Files
    1. 4.1 Schematics
    2. 4.2 PCB Layout
    3. 4.3 Bill of Materials
  11. 5Additional Information
    1.     Trademarks
  12. 6Related Documentation

Analog Operating Mode

Follow the steps below to program the TMAG3101EVM into an analog operating mode and view results.

  1. Verify the TMAG3101EVM is configured for SWIFT operating mode as described in Section 2.3.
  2. Connect to and launch the GUI as described in Section 3.2.1.3.2. When the TMAG3101EVM first connects to the GUI, the firmware performs a read of the full TMAG3101-Q1 EEPROM registers. This typically takes a few seconds to complete. When complete, the EEPROM contents are shown on the Register tab of the GUI.
  3. In the Configuration tab, click the Operating Mode drop-down box and select the "Analog Continuous Conversion" operating mode.
    TMAG3101EVM Analog Operating Mode Figure 3-19 Analog Operating Mode
  4. Configure the desired Magnetic Configuration settings, as shown in Figure 3-20. Select the magnetic channels to enable, angle calculation (if desired), and desired data output from the device. Use the X, Y, and Z range drop-downs to configure the desired sensing range for each axis. If desired, alter the polarity of any axis, enable different levels of filtering or averaging, or alter the angle polarity.
    TMAG3101EVM Magnetic Configuration
              Settings Figure 3-20 Magnetic Configuration Settings
  5. Configure the analog specific configuration settings, as shown in Figure 3-21. Select the desired load drive and enable or disable dynamic scaling on the analog output. For more information on analog output configuration options, please see the TMAG3101-Q1 datasheet.
    TMAG3101EVM Analog Output Configuration
              Settings Figure 3-21 Analog Output Configuration Settings
  6. Select "Program Device" and the GUI programs the TMAG3101EVM according to the configuration and force the EVM into the analog output mode using the SWIFT interface.TMAG3101EVM
    1. To return the TMAG3101-Q1 to SWIFT mode, select "SWIFT mode" from the "Operating Mode" drop-down list and press "Program Device".
  7. To view the data output from the device, go to the Results data tab. Select the desired result plots under the Results to collect/show box in the Results Data tab, and select Collect Data to begin collecting data.TMAG3101EVM
  8. In analog mode, data can also be viewed in the "Analog Detailed Results" tab. Select the appropriate ADC sensing option from the drop down--ADC121C021 for the external ADC or the SCB internal ADC. Remember that these options are only valid depending on which of resistors R5 and R6 are populated or depopulated on the board. This displays the ADC reference voltage for the selection. Select "Start Collection" to see the analog OUT voltage displayed on the meter, as well as the ADC range percentage used.
    TMAG3101EVM Analog Detailed Results Figure 3-22 Analog Detailed Results