SBAU457 October   2026

 

  1.   1
  2.   Description
  3.   Get Started
  4.   Features
  5.   Applications
  6.   6
  7. 1Evaluation Module Overview
    1. 1.1 Introduction
    2. 1.2 Kit Contents
    3. 1.3 Specifications
    4. 1.4 Device Information
  8. 2Hardware
    1. 2.1 TMAG3101-Q1 EVM Components
    2. 2.2 SCB LEDs
    3. 2.3 Hardware Jumper J7 and Resistor Configurations for Different Operating Modes
  9. 3Software
    1. 3.1 Quick Start Setup
    2. 3.2 EVM Operation
      1. 3.2.1 Setup
        1. 3.2.1.1 Driver Installation
        2. 3.2.1.2 Firmware
          1. 3.2.1.2.1 Updating Firmware on SCB
        3. 3.2.1.3 GUI Setup and Usage
          1. 3.2.1.3.1 Initial Setup
          2. 3.2.1.3.2 GUI Operation
      2. 3.2.2 Rotate and Push Demo
      3. 3.2.3 SENT and Triggered SENT Operating Modes
      4. 3.2.4 Analog Operating Mode
      5. 3.2.5 PWM Operating Mode
      6. 3.2.6 Direct EVM Serial Communication
  10. 4Hardware Design Files
    1. 4.1 Schematics
    2. 4.2 PCB Layout
    3. 4.3 Bill of Materials
  11. 5Additional Information
    1.     Trademarks
  12. 6Related Documentation
GUI Operation

To operate the GUI, follow these steps:

  1. Connect to and launch the GUI as described in Section 3.2.1.3.1.

    Close the README.md file page that appears after the EVM connects to the GUI. The text near the bottom-left hand corner of the GUI reads as Hardware Connected.

    TMAG3101EVM Hardware Connected Figure 3-6 Hardware Connected
  2. If Hardware Connected does not show in the bottom-left hand corner of the GUI, then check different hardware COM ports under Options >> Serial Port.
    TMAG3101EVM Change Serial Port Figure 3-7 Change Serial Port
  3. If the hardware still does not connect, then make sure the correct GUI and EVM combination is in use.
  4. Select the Registers icon shown in Figure 3-8 (also available on the left-side menu) to view the EEPROM register map. The GUI performs a complete EEPROM read when the TMAG3101EVM is first connected. This typically takes a few seconds to complete. Once complete, all current EEPROM register settings within the device can be viewed on the Registers tab. You can see EEPROM registers organized into 10 different groups, as shown below. This tab is recommended for viewing register information only. To update the device configuration, use the configuration tab in the GUI. For questions about a register or register bit field, select the TMAG3101EVM icon. For more questions about registers, check the datasheet.
    TMAG3101EVM Registers Page Icon Figure 3-8 Registers Page Icon
    1. EEPROM
    2. Status and Results
  5. Select the Configuration icon shown in Figure 3-9 (also available on the left-side menu) to configure device settings and program different operating modes.
    TMAG3101EVM Configuration Page Icon Figure 3-9 Configuration Page Icon
  6. Select the Plots icon shown in Figure 3-10 (also available on the left-side menu) to view and save graphical data from the TMAG3101-Q1. This screen shows the x-axis, y-axis, z-axis, angle, magnitude, and temperature plots that are derived from the TMAG3101-Q1 output. These plots have been converted to real-world units of mT and degrees. Select the SAVE PLOT button on the corresponding plot to save any specific plot.
    TMAG3101EVM Plots Page Icon Figure 3-10 Plots Page Icon