SBOSAJ5 December 2024 TMP113
PRODUCTION DATA
This register is used to configure the operation of the TMP113 and also provides the alert status.
Return to Register Map.
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| One_Shot | Reserved | Fault[1:0] | Polarity | Alert_Mode | Shutdown | ||
| R/W-0b | R-11b | R/W-00b | R/W-0b | R/W-0b | R/W-0b | ||
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| Conversion_Rate[1:0] | Alert Flag | Reserved | |||||
| R/W-10b | R-1b | R-00000b | |||||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 15 | One_Shot | R/W | 0b | One-shot conversion trigger applicable in shutdown mode
only. In continuous conversion mode the bit reads 0b. In shutdown mode the bit reads
1b, then after the conversion is finished the bit reads 0b. Triggering a one-shot
conversion happens only when the device is in shutdown mode. 0b = Active conversion ongoing 1b = Trigger a one-shot conversion or active conversion complete |
| 14:13 | Reserved | R | 10b | Reserved |
| 12:11 | Fault[1:0] | R/W | 00b | Fault bits are used to set the number of consecutive
conversions for which the alert condition exists before the ALERT
pin is asserted and status bit is set. 00b = 1 fault 01b = 2 faults 10b = 4 faults 11b = 6 faults |
| 10 | Polarity | R/W | 0b | The polarity bit allows the host to adjust the polarity
of the ALERT pin/flag output. 0b = ALERT pin/flag output is active low 1b = ALERT pin/flag output is active high |
| 9 | Alert_Mode | R/W | 0b | The alert mode bit indicates the how the temperature
limits operate. 0b = Comparator mode 1b = Alert mode |
| 8 | Shutdown | R/W | 0b | The shutdown bit is used to change the device conversion mode. 0b = Continuous conversion mode 1b = Shutdown mode |
| 7:6 | Conversion_Rate[1:0] | R/W | 10b | The conversion rate bits configure the device conversion
period. The default is conversion every 250ms. 00b = 4s / 0.25Hz 01b = 1s / 1Hz 10b = 0.25s / 4Hz 11b = 0.125s / 8Hz |
| 5 | Alert flag | R | 1b | The alert bit is a read-only bit which provides the information about the alert status in comparator mode and is affected by Alert_Mode setting. The polarity bit affects the alert flag. |
| 4:0 | Reserved | R | 00000b | Reserved |