over operating free-air temperature range (unless otherwise
noted)(1)
|
MIN |
MAX |
UNIT |
| VCC |
Supply voltage range |
–0.5 |
7 |
V |
| VI |
Input
voltage range(2) |
–0.5 |
7 |
V |
| VO |
Output voltage range(2) |
–0.5 |
VCC
+ 0.5 |
V |
| IIK |
Input clamp current |
VI < 0 |
|
–20 |
mA |
| IOK |
Output clamp current |
VO < 0 or
VO > VCC |
|
±20 |
mA |
| IO |
Continuous
output current |
VO =
0 to VCC |
|
±25 |
mA |
|
Continuous current through VCC or GND |
|
±75 |
mA |
| Tstg |
Storage temperature |
–65 |
150 |
°C |
(1) Stresses beyond those listed under Absolute Maximum Ratings may
cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated under
Recommended Operating Conditions is not implied. Exposure to
absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The input and output voltage ratings may be exceeded if the input and
output current ratings are observed.