When connectors are mated with active signals present, several
failure mechanisms can occur:
- Signal pins make contact before ground/power, causing transient
currents
- Charge transfer between systems at different potentials
(Charged Board Events)
- Current injection into powered-down devices through I/O
pins
- Voltage spikes exceeding device absolute maximum ratings