SDAA352 May 2026 TDA4VH-Q1 , TDA4VL-Q1 , TDA4VM , TDA4VM-Q1
The heartbeat monitoring system was tested with multiple crash scenarios:
Test Case 1: RTOS Core Crash (c7x_1)
- Simulated by halting the C7x DSP
- Detection time: 3 retry cycles
- Recovery: Successful, all cores restored to ALIVE state
Test Case 2: R5F Core Crash (mcu2_0)
- Simulated halting MCU2_0 core
- Detection time: 3 retry cycles
- Recovery: Successful, all cores restored to ALIVE state
Test Case 3: Linux Core Crash (mpu1_0)
- Simulated by killing the rpmsg_char_simple application or by halting the mpu1_0 core
- Detection time: 3 retry cycles
- Recovery: Successful, Linux rebooted and reconnected, all cores restored to ALIVE state