  2.   Abstract
  3. 1Basic Principle of Reverse Wake-up for BQ79616
    1. 1.1 Basic Principle of Reverse Wake-up Implemented by BQ79616 and BQ79600
    2. 1.2 OVUVOTUT Function of BQ79616
    3. 1.3 Logic for BQ79600 to Implement Reverse Wake-up
  4. 2How to Configure BQ79616 and BQ79600 to Achieve Reverse Wake-up Function
    1. 2.1 Configuration for BQ79616 to Implement Reverse Wake-up Function
    2. 2.2 Configuration for BQ79600 to Implement Reverse Wake-up Function
    3. 2.3 Other Configurations for BQ79600 and BQ79616 Prior to Entering Sleep
  5. 3Testing of Reverse Wake-up Based on EVM Board
    1. 3.1 Reverse Wake-up Test with BQ79600 Operating in Sleep Mode
    2. 3.2 Reverse Wake-up Test with BQ79600 Operating in Shutdown Mode
  6. 4Summary
  7. 5References

Reverse Wake-up Test with BQ79600 Operating in Sleep Mode

First, conduct the reverse wake-up test under BQ79600 Sleep mode. Here, it is not necessary to mask the Heartbeat detection of the first AFE. After waking up the system and addressing, run the following code:

#First wake up all chips, perform addressing and configure GPIOs, the test uses GPIO4 as the OT channel

# GPIO4 configured as ADC input and OTUT

90 01 00 0F 08 E1 D7

# Enable TSREF

90 01 03 0A 01 D2 81

# ADC_GO, enable GPIO configuration

90 01 03 0D 0E 90 B5

# Enable Heartbeat and Fault tone for BQ79616

90 01 00 02 03 A4 80

# Configure overvoltage threshold, OV threshold=2700mV

90 01 00 09 02 62 70

# Configures undervoltage threshold, UV threshold=1200mV

90 01 00 0A 00 E3 41

# Enable channels 9 to 16, CELL9-16 ENABLE

90 01 00 0C 00 E0 E1

# Enable channels 1 to 8, CELL0-8 ENABLE

90 01 00 0D 00 E1 71

# Configure over- and under-temperature thresholds, UT 66%, OT 10%

90 01 00 0B 00 E2 D1

# OVUV-GO Round robin with all cells

90 01 03 2C 05 C9 22

# OTUT-GO Round robin with all cells

90 01 03 2D 05 C8 B2

# Enable HB and TONE_RX_EN for BQ79600

90 00 20 01 35 24 50

# If manipulating 0x2001 or 0x2020, CONF_MON_GO must be sent once while resetting RST_REG.

90 00 20 00 20 E4 0F

# Reset INH of BQ79600

90 00 20 02 03 A4 B6

# Re-enable INH of BQ79600

90 00 20 02 00 E4 B7

# Mask all faults of BQ79616 except OVUVOTUT, Heartbeat and Fault tone

91 01 00 16 87 73 E2 8B

# Reset all faults for BQ79616

91 01 03 31 FF FF 71 61

# Reset all faults for BQ79600

90 00 20 30 FF B1 97

# All BQ79616 enter sleep mode

B0 03 09 04 D1 77

# BQ79600 go to Sleep mode

90 00 03 09 04 13 8E

After running the example code, while both the BQ79616 and BQ79600 are in Sleep mode, adjust the cell voltage or temperature or disconnect the communication line to trigger an OVUVOTUT or Heartbeat fault. The logic analyzer data of the test results are shown in Figure 3-3. Triggering a Heartbeat fault by disconnecting the communication line is shown in Figure 3-4.

 Logic Analyzer Data for Implementing OVUVOTUT Reverse Wake-up with BQ79600 Operating in Sleep ModeFigure 3-2 Logic Analyzer Data for Implementing OVUVOTUT Reverse Wake-up with BQ79600 Operating in Sleep Mode
 Logic Analyzer Data for Implementing HB Fail Reverse Wake-up with BQ79600 Operating in Sleep ModeFigure 3-3 Logic Analyzer Data for Implementing HB Fail Reverse Wake-up with BQ79600 Operating in Sleep Mode

Where:

  • D0: 600TX is the TX signal of the UART for communication between the BQ79600 and the MCU.
  • D1: 600RX is the RX signal of the UART for communication between the BQ79600 and the MCU.
  • D2: S1 COMLP is the COML port of the first BQ79616.
  • D3: 600COML is the COML port of the BQ79600.
  • D4: 600CVDD is the CVDD voltage of the BQ79600, used to characterize whether the BQ79600 is in the active state.
  • D5: INH is the INH pin of the BQ79600.

It can be observed that,

  1. At time t1, the BQ79616 enters Sleep mode, the BQ79600 enters Sleep mode, and CVDD is constantly high.
  2. Before time t2, the BQ79600 transmits a Heartbeat tone to the first BQ79616 every 400ms. The BQ79616 also transmits a Heartbeat tone to the subsequent chips every 400ms.
  3. At time t2, an OVUVOTUT or Heartbeat tone fail fault is artificially injected. At this moment, after detecting the fault, the BQ79616 immediately begins transmitting a Fault tone.
  4. Upon receiving the Fault tone, the BQ79600 pulls INH high immediately.