SLLSEU2C March   2017  – December 2024 ISO7710-Q1

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
  7. Absolute Maximum Ratings
  8. ESD Ratings
  9. Recommended Operating Conditions
  10. Thermal Information
  11. 10Power Ratings
  12. 11Insulation Specifications
  13. 12Safety-Related Certifications
  14. 13Safety Limiting Values
  15. 14Electrical Characteristics—5-V Supply
  16. 15Supply Current Characteristics—5-V Supply
  17. 16Electrical Characteristics—3.3-V Supply
  18. 17Supply Current Characteristics—3.3-V Supply
  19. 18Electrical Characteristics—2.5-V Supply 
  20. 19Supply Current Characteristics—2.5-V Supply
  21. 20Switching Characteristics—5-V Supply
  22. 21Switching Characteristics—3.3-V Supply
  23. 22Switching Characteristics—2.5-V Supply
  24. 23Parameter Measurement Information
  25. 24Detailed Description
    1. 24.1 Overview
    2. 24.2 Functional Block Diagram
    3. 24.3 Feature Description
      1. 24.3.1 Electromagnetic Compatibility (EMC) Considerations
    4. 24.4 Device Functional Modes
      1. 24.4.1 Device I/O Schematics
  26. 25Application and Implementation
    1. 25.1 Application Information
    2. 25.2 Typical Application
      1. 25.2.1 Design Requirements
      2. 25.2.2 Detailed Design Procedure
      3. 25.2.3 Application Curve
        1. 25.2.3.1 Insulation Lifetime
    3. 25.3 Power Supply Recommendations
    4. 25.4 Layout
      1. 25.4.1 Layout Guidelines
        1. 25.4.1.1 PCB Material
      2. 25.4.2 Layout Example
  27. 26Device and Documentation Support
    1. 26.1 Documentation Support
      1. 26.1.1 Related Documentation
    2. 26.2 Related Links
    3. 26.3 Receiving Notification of Documentation Updates
    4. 26.4 Support Resources
    5. 26.5 Trademarks
    6. 26.6 Electrostatic Discharge Caution
    7. 26.7 Glossary
  28. 27Revision History
  29. 28Mechanical, Packaging, and Orderable Information

Revision History

Changes from Revision B (October 2020) to Revision C (December 2024)

  • Changed standard name from: "DIN V VDE V 0884-11:2017-01" to: "DIN EN IEC 60747-17 (VDE 0884-17)" throughout the documentGo
  • Deleted references to standard IEC/EN/CSA 60950-1 throughout the documentGo
  • Deleted standard revision and year references from all standard names throughout the document Go
  • Updated the number formatting tables, figures, and cross-references throughout the documentGo
  •  Added "Contact discarge per IEC 61000-4-2" specification of 8000V  Go
  • Changed "Signaling rate" to "Data rate" and added table noteGo
  • Updated maximum power dissipation in the power ratings section.Go
  • Updated distance through isolation, while maintaining other insulation specificationsGo
  • Updated DW-16 package VIORM and VIOWM valuesGo
  • Added TDDB figure reference to VIOWM Go
  • Updated VIOSM, VIOTM, qpd test conditionsGo
  • Updated maximum total current consumption values throughout the supply current characteristics sections.Go
  • Updated maximum propagation delay specifications throughout the switching characteristics sections.Go
  • Updated TDDB plot and the projected lifetime.Go
  • Changed working voltage lifetime margin from: 87.5% to: 50%, minimum required insulation lifetime from: 37.5 years to: 30 years and insulation lifetime per TDDB from: 135 years to: 169 years per DIN EN IEC 60747-17 (VDE 0884-17)Go
  • Changed Figure 25-5 per DIN EN IEC 60747-17 (VDE 0884-17)Go

Changes from Revision A (April 2020) to Revision B (October 2020)

  • Added Functional Safety bullets in Section 1 Go
  • Added D-8 values for TUVGo

Changes from Revision * (March 2017) to Revision A (April 2020)

  • Made editorial and cosmetic changes throughout the document Go
  • Changed From: "Isolation Barrier Life: >40 Years" To: " >100-year projected lifetime at 1500 VRMS working voltage" in Section 1 Go
  • Added "Up to 5000 VRMS isolation rating" in Section 1 Go
  • Added "Up to 12.8 kV surge capability" in Section 1 Go
  • Added "±8 kV IEC 61000-4-2 contact discharge protection across isolation barrier" in Section 1 Go
  • Changed From: "VDE Reinforced Insulation per DIN V VDE V 0884-10 (VDE V 0884-10):2006-12" To: "VDE reinforced insulation per DIN VDE V 0884-11:2017-01" in Section 1 Go
  • Combined CSA, CQC, and TUV bullets into a single bullet with standard names in Section 1 Go
  • Deleted "VDE, UL, CSA, and TUV Certifications for DW-16 package complete; all other certifications planned" bullet in Section 1 Go
  • Updated list of applications in Section 2 sectionGo
  • Updated Figure 3-1 to show two isolation capacitors in series instead of a single isolation capacitor Go
  • Added Climatic categoryGo
  • Updated CSA column and changed DW package to (DW-16)Go
  • Changed tie TYP value from 1.5 to 1 in Switching Characteristics tables throughout the documentGo
  • Corrected ground symbols for "Input (Devices with F suffix)" in Section 24.4.1 Go
  • Fixed Figure 25-2 INPUT wire connection Go
  • Added Section 25.2.3.1 sub-section under Section 25.2.3 section Go
  • Added 'How to use isolation to improve ESD, EFT, and Surge immunity in industrial systems' to Section 26.1 section Go