over operating free-air temperature range (unless otherwise noted)(1) | MIN | MAX | UNIT |
|---|
| VCC1 | Supply voltage, control side | –0.5 | 6 | V |
VOUTx, VEN | Voltage on OUTx pins and EN pin | –0.5 | VCC1 + 0.5(2) | V |
| IO | Output current on OUTx pins | –15 | 15 | mA |
| VINx, VSENSEx | Voltage on IN and SENSE pins | –60 | 60 | V |
| V(ISO,FUNC) | Functional isolation between channels in ISO1212 on the field side | –60 | 60 | V |
| TJ | Junction temperature | –40 | 150 | °C |
| Tstg | Storage temperature | –65 | 150 | °C |
(1) Operation outside the Absolute Maximum Ratings may cause permanent device
damage. Absolute Maximum Ratings do not imply functional operation of
the device at these or any other conditions beyond those listed under
Recommended Operating Conditions. If used outside the Recommended
Operating Conditions but within the Absolute Maximum Ratings, the
device may not be fully functional, and this may affect device reliability,
functionality, performance, and shorten the device lifetime.
(2) Maximum voltage must not exceed 6V.