SLLSFE3A December 2021 – March 2026 TCAN1164-Q1
PRODUCTION DATA
| PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
|---|---|---|---|---|---|---|
| Supply Voltage and Current | ||||||
| ISUP | Supply current Bus biasing active: dominant |
TXD = 0V,
RL = 60Ω, CL = open See Figure 7-2 |
60 | mA | ||
| TXD = 0V,
RL = 50Ω, CL = open See Figure 7-2 |
70 | mA | ||||
| Supply current Bus biasing active: recessive |
TXD = VCCOUT,
RL = 50Ω, CL = open See Figure 7-2 |
3 | mA | |||
| ISUP(STB) | Supply current Standby mode Bus bias autonomous: inactive |
5.5V <
VSUP ≤ 19V See Figure 7-2 |
230 | µA | ||
| ISUP(BIAS) | Supply current Bus bias autonomous: active(1) |
5.5V <
VSUP ≤ 28V See Figure 7-2 |
60 | µA | ||
| UVSUPR | Under voltage VSUP threshold rising | Ramp Up | 4.05 | 4.42 | V | |
| UVSUPF | Under voltage VSUP threshold falling | Ramp Down | 3.9 | 4.25 | V | |
| VCCOUT Characteristics | ||||||
| VCCOUT | 5V regulated output | VSUP = 5.5to 18V IL = 0to 100mA TXD = VCCOUT |
4.9 | 5 | 5.1 | V |
| VCCOUT | 5V regulated output | VSUP =
5.65to 18V IL = 0to 100mA TXD = 0V; VCANH = 0V |
4.9 | 5 | 5.1 | V |
| VCCOUT_DROP | Dropout voltage | 5V LDO, VSUP – VCCOUT, IL = 125mA | 300 | 650 | mV | |
| ∆VCCOUT(∆VSUP) | Line regulation | VSUP = 5.5to 28V, IL = 10mA, ΔVCCOUT | 50 | mV | ||
| ∆VCCOUT(∆VSUPL) | Load regulation | IL = 1to 125mA, VSUP = 14V, ΔVCCOUT | 50 | mV | ||
| UVVCCOUTR | Under voltage VCCOUT threshold rising | Ramp Up | 4.25 | 4.6 | 4.75 | V |
| UVVCCOUTF | Under voltage VCCOUT threshold falling | Ramp Down | 4.2 | 4.45 | 4.7 | V |
| OVCCOUTR | Over voltage VCCOUT threshold rising | Ramp Up | 5.7 | 6.15 | V | |
| OVCCOUTF | Over voltage VCCOUT threshold falling | Ramp Down | 5.47 | 5.65 | V | |
| IL_VCCOUT | Output current limit | VCCOUT short to ground | 175 | 275 | mA | |
| PSRRVCCOUT | Power supply rejection ripple rejection | VRIP = 0.5VPP, Load = 10mA, ƒ = 100Hz, CO = 10μF | 60 | dB | ||