| 7-0 |
SNT[7:0] |
R/W |
0 |
Adds a time offset to the
negative sustain portion of the library waveforms. Some motors have
faster/slower response time than others, therefore this register
allows the user to add or take away negative sustain time from the
library waveforms. Any negative voltage value other than the
overdrive portion is considered a sustain negative value. The offset
is interpreted as two’s complement, so the time offset can be
positive or negative. Sustain Time Negative Offset (ms) = SNT[7:0] ×
PLAYBACK_INTERVAL. |