SLOS879C April 2014 – June 2025 DRV2625
PRODUCTION DATA
In open loop mode, the DRV2625 device drives the waveform as intended by the user.
In LRA closed-loop mode, if a waveform is played without an actuator connected to the OUT+ and OUT– pins, the output pins toggle. However, the toggling frequency is not predictable.
In ERM closed-loop mode, the output pins attempts to drive, however the amplitude is not predictable.