| 7 |
DIAG_RESULT |
R |
0 |
The meaning of this bit changes
depending on the mode of operation. In diagnostics mode, this bit asserts if the
actuator is either open or short to ground, to VDD, oor there is no valid BEMF
signal. For the impedance measurement mode, refer to DIAG_Z_RESULT[7:0]. For the
calibration mode, this bit asserts if the calibration fails. This bit is sticky and
clears on read. |
| 0 |
No issue found. |
| 1 |
Either diagnostics, or calibration
failed. |
| 6-4 |
Reserved |
R/W |
0 |
Reserved |
| 3 |
PROCESS_DONE |
R |
0 |
Shows if the process executed is
done. This bit is sticky and clears on read. |
| 0 |
Process is not done. |
| 1 |
Process is done (either waveform sequencer,
diagnostics or auto-calibration). This bit is cleared when read. |
| 2 |
UVLO |
R |
0 |
If VDD drops below the
UVLO_THRES[2:0], this bit asserts. This bit is sticky and clear on read. |
| 0 |
No VDD droop has been observed. |
| 1 |
A VDD droop is observed. Clears on
read. |
| 1 |
OVER_TEMP |
R |
0 |
Shows current status of the
thermal protection. This bit is sticky and clears on read. |
| 0 |
Temperature is below over-temperature
threshold |
| 1 |
Temperature is above over-temperature
threshold. Clears on read. |
| 0 |
OC_DETECT |
R |
0 |
Shows current status of the
output overcurrent protection. This bit is sticky and clears on read. |
| 0 |
No over-current detected in OUT+ or
OUT- |
| 1 |
Over-current detected in OUT+ or OUT-.
Clears on read. |