SLOS893D September 2014 – August 2025 DRV2624
PRODUCTION DATA
The rated voltage is the driving voltage that the driver outputs during steady state. However, in closed-loop drive mode, temporarily having an output voltage that is higher than the rated voltage is possible.
The RATED_VOLTAGE[7:0] parameter sets the rated voltage for the closed-loop drive modes.
In open-loop mode, the RATED_VOLTAGE[7:0] parameter is ignored. Instead, the OD_CLAMP[7:0] parameter is used to set the full-scale voltage for the open-loop drive modes.
The auto-calibration routine uses the RATED_VOLTAGE[7:0] and OD_CLAMP[7:0] bits as inputs and therefore these registers must be written before calibration is performed. Any modification of this register value is followed by calibration to appropriately set A_CAL_BEMF[7:0].